Connections (continued)<br />

<strong>Twido</strong> programmable <strong>controller</strong><br />

Analog I/O extension modules<br />

Connections (continued)<br />

Mixed input/output modules<br />

TM2 AMM 6HT<br />

Voltage configuration<br />

Current configuration<br />

1<br />

0-10 V<br />

+<br />

–<br />

V0<br />

I0<br />

IN 0<br />

4-20 mA<br />

+<br />

–<br />

V0<br />

I0<br />

IN 0<br />

0-10 V<br />

0-10 V<br />

+<br />

–<br />

+<br />

–<br />

COM<br />

V1<br />

I1<br />

V2<br />

I2<br />

IN 1<br />

IN 2<br />

4-20 mA<br />

4-20 mA<br />

+<br />

–<br />

+<br />

–<br />

COM<br />

V1<br />

I1<br />

V2<br />

I2<br />

IN 1<br />

IN 2<br />

2<br />

0-10 V<br />

+<br />

–<br />

COM<br />

V3<br />

I3<br />

IN 3<br />

4-20 mA<br />

+<br />

–<br />

COM<br />

V3<br />

I3<br />

IN 3<br />

3<br />

– +<br />

24 V Fu<br />

+<br />

Voltage preactuator<br />

–<br />

+<br />

– 24 V<br />

NC<br />

VI0<br />

COM<br />

OUT 0<br />

– +<br />

24 V Fu<br />

+<br />

Current<br />

preactuator<br />

–<br />

+<br />

– 24 V<br />

NC<br />

VI0<br />

COM<br />

OUT 0<br />

4<br />

Voltage preactuator<br />

+<br />

–<br />

S0<br />

VI1<br />

COM<br />

OUT 1<br />

Current<br />

preactuator<br />

+<br />

–<br />

S0<br />

VI1<br />

COM<br />

OUT 1<br />

5<br />

S1<br />

S1<br />

d Do not connect any wires to an unused channel.<br />

TM2 AMM 3HT<br />

TM2 ALM 3LT<br />

6<br />

– +<br />

c 24 V<br />

Fu<br />

+<br />

–<br />

c 24 V<br />

–<br />

+<br />

c 24 V<br />

Fu<br />

+<br />

–<br />

c 24 V<br />

Voltage/current<br />

preactuator<br />

+<br />

–<br />

+<br />

–<br />

OUT<br />

Voltage/current<br />

preactuator<br />

+<br />

–<br />

+<br />

–<br />

OUT<br />

7<br />

NC<br />

A'<br />

A<br />

NC A<br />

0-10 V 4-20 mA<br />

Voltage/current<br />

sensor<br />

0-10 V 4-20 mA<br />

+<br />

–<br />

+<br />

–<br />

+<br />

–<br />

NC<br />

+<br />

–<br />

IN 0<br />

IN 1<br />

Pt 100<br />

temperature probe<br />

+<br />

–<br />

Thermocouple K, J, T<br />

B'<br />

B<br />

+<br />

B'<br />

–<br />

B<br />

NC<br />

A<br />

+<br />

B'<br />

–<br />

B<br />

IN 0<br />

IN 1<br />

8<br />

Fu: 2 A delayed fuse<br />

v For a Pt 100 3-wire temperature probe (RTD), connect the three wires to terminals A, B’ and<br />

B (channels IN0 and IN1).<br />

v For a Pt 100 2-wire temperature probe (RTD), connect the two wires to terminals A and B’ and<br />

make a bridge between B’ and B (channels IN0 and IN1).<br />

v For a thermocouple, connect the two wires to terminals B’ and B (channels IN0 and/or IN1).<br />

d Do not connect any wires to an unused channel.<br />

9<br />

10<br />

Presentation:<br />

page 50<br />

Description:<br />

page 50<br />

Characteristics:<br />

pages 51 …<br />

References:<br />

page 54<br />

Dimensions:<br />

page 55<br />

59