Description,<br />

characteristics,<br />

references<br />

<strong>Twido</strong> programmable <strong>controller</strong> 0<br />

Ethernet TCP/IP network<br />

<strong>Twido</strong> compact base <strong>controller</strong>s with integrated Ethernet<br />

port<br />

<strong>Twido</strong> compact base <strong>controller</strong> with display<br />

10 11<br />

9<br />

1 2<br />

8<br />

7<br />

3<br />

4<br />

5<br />

6<br />

The <strong>Twido</strong> programmable <strong>controller</strong> range offers 2 compact base <strong>controller</strong>s with<br />

integrated Ethernet port. Within a compact overall size of 157 x 90 x 70 mm, base<br />

<strong>controller</strong>s TWD LCAE 40DRF (a 100…240 V supply) and TWD LCDE 40DRF<br />

(c 24 V supply) comprise the following discrete I/O:<br />

b 24 c 24 V inputs.<br />

b 14 relay outputs.<br />

b 2 c 24 V transistor outputs.<br />

These base <strong>controller</strong>s with real-time clock function can be tted with:<br />

b Up to 7 I/O expansion modules, so increasing the I/O capacity to 152 (screw<br />

terminal version) or 264 (HE 10 connector version).<br />

b Any of the separate components in the <strong>Twido</strong> range (memory cartridge, serial link<br />

adapters, digital display).<br />

Description<br />

<strong>Twido</strong> compact base <strong>controller</strong>s with integrated Ethernet port<br />

TWD LCAE/LCDE 40DRF comprise:<br />

1 A mini-DIN type RS 485 serial port connector (allowing connection of the<br />

programming terminal).<br />

2 A slot for digital diagnostic/maintenance display module.<br />

3 A screw terminal block for supply to the c 24 V sensors (only on base <strong>controller</strong><br />

TWD LCAE 40DRF) and for connection of the input sensors (protected by hinged<br />

terminal block cover).<br />

4 A connector for expansion modules (7 modules max.: discrete I/O, analogue I/O,<br />

CANopen bus, AS-Interface).<br />

5 A display block.<br />

6 A screw terminal block for connection of the output preactuators (protected by a<br />

hinged terminal block cover).<br />

7 Two analogue adjustment points.<br />

8 A connector for extension of the 2 nd RS 232C/RS 485 serial port.<br />

9 A screw terminal block for connection of the mains power supply (a or c).<br />

With access through the bottom of the <strong>controller</strong>:<br />

10 A memory cartridge connector.<br />

11 A standard connector for 10BASE-T/100BASE-TX (RJ45) interface module.<br />

Characteristics<br />

Base <strong>controller</strong> type TWD LCAE 40DRF TWD LCDE 40DRF<br />

TransparentReady Class<br />

A10<br />

Services<br />

Web services<br />

No Web server<br />

Basic Ethernet TCP/IP communication<br />

services<br />

Modbus messaging (read/write of data words)<br />

Client BOOTP for assignment of IP address by the FDR server (1)<br />

Structure Physical interface 10BASE-T/100BASE-TX, standard RJ45 type connector<br />

Binary rate<br />

10/100 Mbit/s with automatic recognition<br />

Medium<br />

Twisted pair<br />

Compact base<br />

<strong>controller</strong><br />

Supply voltage Nominal a 100…240 V, 50/60 Hz c 24 V<br />

Limits a 85…264 V, 47…63 Hz 19.2…30 V<br />

c 24 V sensor supply 250 mA –<br />

Inputs<br />

24 c 24 V inputs, 11 and 7 mA, type 1 (positive or negative logic)<br />

Outputs<br />

14 relay outputs, a 230 V or c 30 V, 2 A<br />

2 transistor outputs, c 24 V, 1 A (positive logic)<br />

Expansion modules<br />

7 modules max.: Discrete I/O (see page 42), analogue I/O (see page 54), CANopen bus (see<br />

page 69) and AS-Interface system (see page 73)<br />

Other characteristics See pages 10 and 12<br />

LED indicator<br />

Controller status (PWR, RUN, ERR and STAT), I/O status (INp/OUTp)<br />

Ethernet status (LAN ST), 10 or 100 Mbit/s rate (L ACT)<br />

References<br />

Description<br />

Compact base<br />

<strong>controller</strong>s with<br />

integrated<br />

Ethernet port<br />

Transparent Ready<br />

Class A10<br />

No. of<br />

discrete I/O<br />

24 a 24 V inputs<br />

14 relay outputs<br />

2 solid state<br />

outputs<br />

c 24 V<br />

Supply<br />

voltage<br />

Reference<br />

Weight<br />

kg<br />

a 100…240 V TWD LCAE 40DRF 0.525<br />

c 24 V TWD LCDE 40DRF 0.525<br />

Separate components: serial interface adapter, memory cartridge, digital display, see page 13.<br />

TWD LCpE 40DRF<br />

(1) Auto MDI/MDX function not supported.<br />

64