Connections,<br />

references<br />

<strong>Twido</strong> programmable <strong>controller</strong> 0<br />

Modbus and character mode serial link<br />

Cabling system<br />

Modbus cabling system<br />

Non isolated link<br />

Isolated link<br />

2<br />

6 2<br />

1<br />

5<br />

1 1<br />

c<br />

g b b g b b<br />

24 V<br />

Magelis<br />

XBT N slave<br />

Modular<br />

Phaseo<br />

7<br />

6<br />

7<br />

8<br />

6<br />

6<br />

7<br />

<strong>Twido</strong> master<br />

TeSys U Altivar 31 <strong>Twido</strong> master<br />

Altivar 31<br />

TeSys U<br />

- Cable length between <strong>Twido</strong> and Altivar 31: y 30 m<br />

- Total length of cables between tap isolation boxes 1: y 1000 m<br />

- Length of cable 6: y 10 m<br />

- Length of tap link cables 6, 7 or 8: y 10 m<br />

<strong>Twido</strong><br />

slave<br />

g Line polarisation active<br />

b Line end adapter<br />

References<br />

g Line polarisation active<br />

b Line end adapter<br />

Tap-off and adapter components for RS 485 serial link<br />

Description Application Item Length Reference Weight<br />

kg<br />

Tap isolation box<br />

Screw terminal block<br />

for main cable<br />

2 x RJ45 for tap-off<br />

-<br />

RS 485 line isolation (1)<br />

-<br />

Line end adapter (RC 120 Ω, 1nF)<br />

-<br />

Line pre-polarisation (2 R 620 Ω)<br />

c 24 V supply (screw terminal block)<br />

or c 5 V (via RJ45)<br />

Mounting on 35 mm 5<br />

1 – TWD XCA ISO 0.100<br />

TWD XCA ISO<br />

TWD XCA T3RJ<br />

Tap junction box<br />

1 x RJ45 for main cable<br />

2 x RJ45 for tap-off<br />

-<br />

Line end adapter (RC 120 Ω, 1nF)<br />

-<br />

Line pre-polarisation (2 R 620 Ω)<br />

Mounting on 35 mm 5<br />

2 – TWD XCA T3RJ 0.080<br />

Modbus hub<br />

Screw terminal block<br />

for main cable<br />

10 x RJ45 for tap-off<br />

Mounting on 35 mm 5, on mounting<br />

plate or panel (2 x Ø 4 mm screws)<br />

– – LU9 GC3 0.500<br />

T-junction boxes<br />

2 x RJ45<br />

for main cable<br />

1 integrated cable with RJ45<br />

connector for Altivar variable<br />

speed <strong>controller</strong> dedicated tap-off<br />

– 0.3 m VW3 A8 306 TF03 –<br />

1 m VW3 A8 306 TF10 –<br />

LU9 GC3<br />

Passive tap<br />

junction box<br />

-<br />

Line extension and single-channel<br />

tap-off on screw terminal block<br />

-<br />

Line end adapter<br />

– – TSX SCA 50 0.520<br />

RS 232C/RS 485<br />

line converter<br />

-<br />

Flow rate 19.2 Kbit/s max.<br />

-<br />

Without modem signals<br />

c 24 V/20 mA supply,<br />

Mounting on 35 mm 5<br />

– – XGS Z24 0.100<br />

TSX SCA 50<br />

XGS Z24<br />

(1) Line isolation recommended for distances > 10 m.<br />