USING THE OVEN<br />
4. FUNCTIONAL LEVELS C2 AND<br />
C3<br />
4.1 TURNING ON THE OVEN<br />
To turn on the oven, simply rotate main switch/selector knob S1<br />
from "0" to the required cooking cycle. The following sequence<br />
then occurs:<br />
L1<br />
S1<br />
0<br />
accforno alp eps<br />
4.1.1. ON ALL MODELS<br />
- Green indicator led L1 illuminates;<br />
- Thermometer/Thermostat display TS indicates the oven temperature;<br />
- The oven light switches on.<br />
4.1.2. MODELS WITH STEAM BOILER<br />
- The boiler starts filling.<br />
genva_l_alp2.eps<br />
(flashing led);<br />
- The boiler starts heating up.<br />
genvapor_alp.eps<br />
(fixed illuminated led);<br />
- The boiler is ready (led off)<br />
4.1.3 TURNING OFF THE OVEN<br />
To turn off the oven, simply <strong>return</strong> selector knob S1 back to "0".<br />
C1<br />
C2<br />
C3<br />
49<br />
4.2. SELECTING THE COOKING CYCLE<br />
Set selector S1 to the required cooking cycle, for example, the<br />
"mixed cooking cycle" (the cooking cycle may also be selected<br />
even after cooking has started).<br />
L1 S1<br />
0<br />
CR<br />
C4<br />
modocott alp eps<br />
4.3. SETTING THE COOKING TEMPERATURE<br />
- Turn thermostat knob TS clockwise.<br />
- The temperature setting immediately starts flashing on the<br />
display.<br />
TS<br />
200<br />
t tt l<br />
60<br />
100<br />
150<br />
C1<br />
C2<br />
C3<br />
- Stop the knob at the temperature setting required, for example,<br />
200°C.<br />
200<br />
t 200 l<br />
After about 5 seconds, the display stops flashing and restores the<br />
current oven temperature.<br />
Note: Each cooking cycle (C1, C2, etc. - see paragraph above)<br />
has its own maximum temperature limit beyond which temperature<br />
control knob TS cannot be turned.<br />
In the case of steam cycle C3, no temperature setting is<br />
required since the cycle is automatically set at 100°C.<br />
60<br />
100<br />
150<br />
TS<br />
GB