6.14.4 REGENERATION PROGRAM Cr<br />
On functional level ovens C6, regeneration cycle Cr is preprogrammed<br />
and hence cannot be deleted. To set the regeneration<br />
cycle, select automatic mode and, using the up and down arrow<br />
buttons, set Cr on the program display.<br />
The regeneration cycle comprises one single phase featuring:<br />
- a special humidity-controlled cooking cycle;<br />
- a preset temperature of 140°C (modifiable);<br />
- the use of full power;<br />
- continuous cooking (Cont). Once started, the regeneration<br />
cycle also continues even if the oven door is opened.<br />
Important! Risk of burning.<br />
Open the door with due care when the appliance is hot.<br />
The generation cycle may also be programmed for a set time or<br />
used in conjunction with the core temperature probe.<br />
6.14.5 DELETING A SAVED PROGRAM<br />
1) In AUTO mode, simultaneously press buttons M and ESC for<br />
two seconds as described above.<br />
M<br />
RETURN CANCEL<br />
biblio2_alp.eps<br />
2) The program display is initially set to program 1.<br />
PROGRAM<br />
progr_1_alp.eps<br />
3) Using the up and down arrow buttons, enter the number of the<br />
program to be deleted, i.e. Program 5.<br />
PROGRAM<br />
progr_5_alp.eps<br />
Program 5 is now displayed (fixed illuminated led).<br />
4) Press button AC for two seconds.<br />
M<br />
RETURN CANCEL<br />
biblioac_alp.eps<br />
59<br />
Program 5 now flashes on the display indicating that it has been<br />
deleted.<br />
PROGRAM<br />
progr_5_2alp.eps<br />
Note: If necessary, you can then delete other programs by<br />
repeating the steps described in points 3 and 4 above. Regeneration<br />
program Cr is instead protected and cannot therefore be<br />
deleted.<br />
When you have finished, simultaneously press buttons M and<br />
ESC for 2 seconds to close the program memory and save the<br />
changes made.<br />
M<br />
RETURN CANCEL<br />
biblio2_alp.eps<br />
Note: If you inadvertently delete the wrong program, simply press<br />
the ESC button as previously described in paragraph 6.14.2 to<br />
close the program memory without saving any changes.<br />