Adabas Transaction Manager Messages and Codes - Software AG ...
Adabas Transaction Manager Messages and Codes - Software AG ...
Adabas Transaction Manager Messages and Codes - Software AG ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Adabas</strong> Response <strong>Codes</strong><br />
Response 79<br />
Origin<br />
Open Systems<br />
If it is an FST problem, reorder the database. If it is a DSST problem, which can only occur in<br />
the context of a utility, refer to the message DSSTALL for further information.<br />
Mainframe <strong>and</strong> open systems<br />
Explanation The meaning of this response code varies, depending on whether you are using <strong>Adabas</strong> on<br />
mainframe systems or <strong>Adabas</strong> on open systems.<br />
Action<br />
98<br />
Mainframe Systems<br />
A collation descriptor exit or hyperdescriptor exit error occurred. The following table describes<br />
the possible subcodes for this response code <strong>and</strong> their meanings:<br />
Subcode Meaning<br />
1<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
Open Systems<br />
Either a collation descriptor exit (subcode CDXn where n is the one-byte binary<br />
collation descriptor exit number) or a hyperdescriptor exit ("hyperdescriptor exit")<br />
was not specified ADARUN.<br />
The hyperdescriptor exit stub was called for an extended MU/PE file.<br />
Improper use of the parameter list was detected by the Hyperdescriptor Exit Stub.<br />
The most likely reason is that a hyperdescriptor exit using the <strong>Adabas</strong> 8 parameter<br />
structures is linked to the Hyperdescriptor Exit Stub.<br />
The Hyperdescriptor Exit Stub could not resolve the HEXOLD external reference.<br />
Improper use of the parameter list was detected. The second word of the parameter<br />
list was modified.<br />
A hyperdescriptor exit did not return an output parameter area address.<br />
A hyperdescriptor exit rejected the call by setting a nonzero return code in the output<br />
parameter header.<br />
A hyperdescriptor exit is not available to the nucleus. The following information is returned<br />
in the Additions 2 field of the control block:<br />
■ The first two bytes contain the number of the hyperdescriptor exit,;<br />
■ The third <strong>and</strong> fourth bytes contain the name of the hyperdescriptor.<br />
The method of resolving the error varies, depending on whether you are using <strong>Adabas</strong> on<br />
mainframe systems or <strong>Adabas</strong> on open systems.<br />
Mainframe Systems<br />
The following table describes the actions you should take for each possible subcode for this<br />
response code:<br />
<strong>Adabas</strong> <strong>Transaction</strong> <strong>Manager</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong>