Subcode Meaning<br />
22<br />
23<br />
24<br />
25<br />
26<br />
27<br />
28<br />
30<br />
31<br />
n<br />
254<br />
255<br />
Invalid local time – (non-existing local time in the gap that occurs when switching<br />
from st<strong>and</strong>ard to daylight saving time or when the time zone advances GMT<br />
offset)<br />
Year outside range of 1-9999.<br />
Month outside range of 1-12.<br />
Day outside range of 1-n.<br />
Hours outside range of 0-24.<br />
Minutes outside range of 0-59.<br />
Seconds outside range of 0-59.<br />
Accessing a field defined with option TZ but no time zone was specified in the<br />
user session. Issue the OP comm<strong>and</strong> with TZ='timezone' parameter in the record<br />
buffer to set the time zone for the user session.<br />
Invalid daylight saving offset given (fldD) for date-time <strong>and</strong> time zone.<br />
Data between user <strong>and</strong> system data representation could not be converted without<br />
error <strong>and</strong> 2-byte error code from ECS.<br />
Numeric field length in format shorter than the field length in the FDT.<br />
Field length exceeded maximum for variable fields.<br />
Entire Conversion Service (ECS) error codes are described in Entire Conversion Service (ECS)<br />
Errors, elsewhere in the <strong>Adabas</strong> <strong>Messages</strong> documentation.<br />
Open Systems<br />
A format, length conversion, or truncation error occurred while processing field values in the<br />
record buffer or value buffer.<br />
■ The value for an FI field is too long;<br />
■ The resulting value exceeds the border of the FI field;<br />
■ Truncation error of numeric field;<br />
■ Truncation of alphanumeric fields or truncation of numeric fields which are converted to<br />
alphanumeric, except when OPTIONS=TRUNCATION is enabled in ADANUC;<br />
■ A value defined without LA or L4 option with variable length is larger than 253 bytes. This<br />
may happen for Unicode fields after conversion to another encoding.<br />
■ The length specified for a Unicode field for a character set with fixed character length is<br />
not a multiple of the character length: in particular, the length for UTF-16 based character<br />
sets must be a multiple of 2, <strong>and</strong> the length for UTF-32 based character sets must be a<br />
multiple of 4;<br />
■ The specified value is not a valid date/time value;<br />
■ The field does not contain a valid date/time value. This can happen if the value was stored<br />
without a date/time edit mask;<br />
■ A date/time field with option TZ was specified in the format or search buffer, but there was<br />
no time zone specified in an OP comm<strong>and</strong> for the current <strong>Adabas</strong> user session;<br />
<strong>Adabas</strong> <strong>Transaction</strong> <strong>Manager</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong><br />