Adabas Transaction Manager Messages and Codes - Software AG ...
Adabas Transaction Manager Messages and Codes - Software AG ...
Adabas Transaction Manager Messages and Codes - Software AG ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Response 9<br />
Origin<br />
Mainframe <strong>and</strong> open systems<br />
Explanation The meaning of this response code varies, depending on whether you are using <strong>Adabas</strong> on<br />
mainframe systems or <strong>Adabas</strong> on open systems.<br />
Mainframe Systems<br />
A subcode indicating the specific cause <strong>and</strong> action for this response code appears in the<br />
low-order (rightmost) two bytes of the ACB's Additions 2 field or in the ACBX's Error Subcode<br />
(ACBXERRC) field. The following are the subcodes <strong>and</strong> their meanings:<br />
Subcode Meaning<br />
1<br />
2<br />
3<br />
15<br />
The user was backed out because the hold queue was full<br />
Action: Set the number of hold queue elements (ADARUN NH parameter) higher,<br />
or tune the application to issue more frequent ET comm<strong>and</strong>s.<br />
The transaction time limit (TT) has been exceeded, <strong>and</strong> the transaction was backed<br />
out.<br />
Action: Correct the cause of the timeout, then restart the transaction.<br />
One of the following is the case:<br />
■ The transaction non-activity time limit (TNAE, TNAX, or TNAA) has been<br />
exceeded.<br />
■ The user was stopped by the STOPF or STOPI operator, or an <strong>Adabas</strong> Online<br />
System comm<strong>and</strong>.<br />
■ A security violation response code has been returned for an ET-logic user.<br />
Information about response codes for security violations is provided in the <strong>Adabas</strong><br />
Security documentation.<br />
■ When a new user issues an OP cmd with the same user ID (in ADD1) as an earlier<br />
user did <strong>and</strong> the earlier user was inactive for more than 60 seconds, the new user<br />
can, by issuing a second OP cmd again (the first OP cmd will get response code<br />
9, subcode 64), take over the user ID of the earlier user. When the earlier user<br />
becomes active again, this subcode can be received.<br />
Action: Correct the cause of the timeout, then restart the transaction.<br />
The user was backed out because a pending Work area overflow occurred during<br />
this operation.<br />
Action: Either reduce the transaction length to lessen the data protection area<br />
requirement, or increase the protection area on Work.<br />
<strong>Adabas</strong> <strong>Transaction</strong> <strong>Manager</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong><br />
<strong>Adabas</strong> Response <strong>Codes</strong><br />
51