<strong>Adabas</strong> Response <strong>Codes</strong><br />
Action<br />
Response 42<br />
Origin<br />
Explanation<br />
74<br />
■ Invalid index usage;<br />
■ A descending index range was specified;<br />
■ A double index was used for a non-periodic field;<br />
■ A multiple-value field with an index specification <strong>and</strong> a multiple-value field without an<br />
index specification were used;<br />
■ A value cannot be converted to the required format (READ comm<strong>and</strong>) or converted to the<br />
FDT st<strong>and</strong>ard format (UPDATE comm<strong>and</strong>);<br />
■ The S element was applied to a field that does not have the NC option;<br />
■ A field with the NC option was used more than once together with its S element;<br />
■ The add option is not compatible with the format/length;<br />
■ The specification of a charater set was invalid;<br />
■ A field was specified with an edit mask not allowed for the field;<br />
■ A field segment notation (byte-number,length) or (byte-number,length,length-2)<br />
was not correct. Values for byte-number + length must be less than or equal to the<br />
maximum value length + 1, <strong>and</strong> length-2 must be equal to length. The maximum<br />
value for LB fields is 2,147,483,643, for LA fields 16381, an for other values 253 bytes;<br />
■ Segment notation is only allowed for values with the format "A".<br />
The following information is returned in the Additions 2 field of the control block:<br />
■ The leftmost two bytes contain the number of the byte (in binary format) relative to the<br />
beginning of the format buffer where the error was detected.<br />
■ The rightmost two bytes contain the name of the field being processed when the error was<br />
detected.<br />
Correct the specification error <strong>and</strong> reissue the comm<strong>and</strong> or job. For more information about<br />
syntax rules for multiple field <strong>and</strong> periodic group indexing, refer to the <strong>Adabas</strong> Comm<strong>and</strong><br />
Reference documentation.<br />
Mainframe systems only<br />
A space problem occurred. The following are the subcodes <strong>and</strong> their meanings:<br />
Subcode Meaning<br />
1<br />
2<br />
The Work pool was too small to store a user format.<br />
Action: Increase the LWP specification <strong>and</strong> retry .<br />
The internal format buffer was too small to store a user format (translated into<br />
internal structure).<br />
Action: Increase LFP specification <strong>and</strong> retry.<br />
<strong>Adabas</strong> <strong>Transaction</strong> <strong>Manager</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong>