<strong>Adabas</strong> Response <strong>Codes</strong><br />

Action<br />

Response 42<br />

Origin<br />

Explanation<br />

74<br />

■ Invalid index usage;<br />

■ A descending index range was specified;<br />

■ A double index was used for a non-periodic field;<br />

■ A multiple-value field with an index specification <strong>and</strong> a multiple-value field without an<br />

index specification were used;<br />

■ A value cannot be converted to the required format (READ comm<strong>and</strong>) or converted to the<br />

FDT st<strong>and</strong>ard format (UPDATE comm<strong>and</strong>);<br />

■ The S element was applied to a field that does not have the NC option;<br />

■ A field with the NC option was used more than once together with its S element;<br />

■ The add option is not compatible with the format/length;<br />

■ The specification of a charater set was invalid;<br />

■ A field was specified with an edit mask not allowed for the field;<br />

■ A field segment notation (byte-number,length) or (byte-number,length,length-2)<br />

was not correct. Values for byte-number + length must be less than or equal to the<br />

maximum value length + 1, <strong>and</strong> length-2 must be equal to length. The maximum<br />

value for LB fields is 2,147,483,643, for LA fields 16381, an for other values 253 bytes;<br />

■ Segment notation is only allowed for values with the format "A".<br />

The following information is returned in the Additions 2 field of the control block:<br />

■ The leftmost two bytes contain the number of the byte (in binary format) relative to the<br />

beginning of the format buffer where the error was detected.<br />

■ The rightmost two bytes contain the name of the field being processed when the error was<br />

detected.<br />

Correct the specification error <strong>and</strong> reissue the comm<strong>and</strong> or job. For more information about<br />

syntax rules for multiple field <strong>and</strong> periodic group indexing, refer to the <strong>Adabas</strong> Comm<strong>and</strong><br />

Reference documentation.<br />

Mainframe systems only<br />

A space problem occurred. The following are the subcodes <strong>and</strong> their meanings:<br />

Subcode Meaning<br />

1<br />

2<br />

The Work pool was too small to store a user format.<br />

Action: Increase the LWP specification <strong>and</strong> retry .<br />

The internal format buffer was too small to store a user format (translated into<br />

internal structure).<br />

Action: Increase LFP specification <strong>and</strong> retry.<br />

<strong>Adabas</strong> <strong>Transaction</strong> <strong>Manager</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong>