13.12.2012 Views

Adabas Transaction Manager Messages and Codes - Software AG ...

Adabas Transaction Manager Messages and Codes - Software AG ...

Adabas Transaction Manager Messages and Codes - Software AG ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Adabas</strong> Response <strong>Codes</strong><br />

Action<br />

Response 252<br />

Origin<br />

Explanation<br />

Action<br />

Response<br />

253<br />

Origin<br />

Subcode Meaning<br />

22<br />

25<br />

26<br />

27<br />

28<br />

29<br />

30<br />

An attempt was made to assign a user remotely but Entire Net-Work is not active.<br />

No system image target<br />

System image target changed<br />

Internal error.<br />

Version mismatch between the PLXCB <strong>and</strong> the SVCCLU part of the ADASVC.<br />

Probably, you used a NUCID value from a restricted range. Otherwise, this is an<br />

internal error.<br />

Action: Ensure that the NUCID assignments are valid.<br />

More than 32 NUCIDs were detected for the same SVC/DBID combination.<br />

Action: Reduce the number of NUCIDs on the SVC/DBID to 32.<br />

On open systems, an invalid utility call - versions conflict occurred.<br />

For internal errors on mainframe systems, contact your <strong>Software</strong> <strong>AG</strong> technical support<br />

representative. For all other mainframe errors except as noted, contact your systems<br />

administrator.<br />

On open systems, check whether the utilities <strong>and</strong> database nuclei are of the same version.<br />

Contact your <strong>Software</strong> <strong>AG</strong> technical support representative for assistance.<br />

Mainframe <strong>and</strong> open systems<br />

On mainframe systems, an error occurred during <strong>Adabas</strong> SVC processing (post error).<br />

Note: If you are running with Entire Net-Work, the leftmost two bytes of the Additions 2<br />

field (in the ACB) or the ACBXERRC field (in the ACBX) may contain the ID of the Entire<br />

Net-Work node that issued this response code.<br />

On open systems, an invalid subroutine call - coding error occurred. This response may also<br />

be returned on setting the Entire Net-Work timeout via Adaset Timeout if Entire Net-Work<br />

is not correctly installed.<br />

For open systems, contact your <strong>Software</strong> <strong>AG</strong> technical support representative.<br />

Mainframe <strong>and</strong> open systems<br />

Explanation On mainframe systems, an error occurred processing a buffer.<br />

184<br />

Note: If you are running with Entire Net-Work, the leftmost two bytes of the Additions 2<br />

field (in the ACB) or the ACBXERRC field (in the ACBX) may contain the ID of the Entire<br />

Net-Work node that issued this response code.<br />

<strong>Adabas</strong> <strong>Transaction</strong> <strong>Manager</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!