Adabas Transaction Manager Messages and Codes - Software AG ...
Adabas Transaction Manager Messages and Codes - Software AG ...
Adabas Transaction Manager Messages and Codes - Software AG ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Adabas</strong> Response <strong>Codes</strong><br />
Action<br />
Response 211<br />
Origin<br />
Explanation<br />
Action<br />
Response 212<br />
Origin<br />
Explanation<br />
Action<br />
Response 213<br />
Origin<br />
Explanation<br />
152<br />
On open systems, the DBA may increase the value of the NAB or NC parameters in the<br />
NETRDI in the target node.<br />
Mainframe <strong>and</strong> open systems<br />
On mainframe systems, an invalid ID table index in the UB (internal error) occurred.<br />
Note: If you are running with Entire Net-Work, the leftmost two bytes of the Additions 2<br />
field (in the ACB) or the ACBXERRC field (in the ACBX) may contain the ID of the Entire<br />
Net-Work node that issued this response code.<br />
On open systems, a remote utility cannot be executed because OPTIONS = LOCAL_UTILITIES<br />
is set for the database.<br />
On open systems, contact the DBA of the remote database.<br />
Mainframe <strong>and</strong> open systems<br />
On mainframe systems, an invalid input/output buffer was encountered for an internal<br />
comm<strong>and</strong>.<br />
On open systems, a requested function is not implemented in the target architecture.<br />
On open systems, execute the utility on the target node.<br />
Mainframe systems only<br />
ID table not found (SVC not properly installed).<br />
Note: If you are running with Entire Net-Work, the leftmost two bytes of the Additions 2<br />
field (in the ACB) or the ACBXERRC field (in the ACBX) may contain the ID of the Entire<br />
Net-Work node that issued this response code.<br />
The following table describes the possible subcodes that might occur if an <strong>Adabas</strong> DBID/SVC<br />
routing table error occurs:<br />
Subcode Meaning<br />
16<br />
20<br />
The specified SVC number does not correspond to a currently installed SVC on<br />
the z/OS or z/VSE system. Check to be sure that the specified SVC number is correct<br />
<strong>and</strong>, if it is, ensure that an <strong>Adabas</strong> SVC is installed using that SVC number.<br />
The specified SVC number corresponds to an installed SVC on the z/OS or z/VSE<br />
system, but the SVC is not an <strong>Adabas</strong> SVC. Ensure that the provided SVC number<br />
is correct <strong>and</strong>, if it is, determine why the SVC installed for that number is not an<br />
<strong>Adabas</strong> SVC for z/OS or z/VSE.<br />
<strong>Adabas</strong> <strong>Transaction</strong> <strong>Manager</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong>