13.12.2012 Views

Adabas Transaction Manager Messages and Codes - Software AG ...

Adabas Transaction Manager Messages and Codes - Software AG ...

Adabas Transaction Manager Messages and Codes - Software AG ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Subcode Meaning<br />

60<br />

65<br />

70<br />

72<br />

74<br />

81<br />

86<br />

■ Sx with the ISN Lower Limit field specified<br />

Action: Review application program <strong>and</strong> the file parameter Enable ISN<br />

Positioning.<br />

A memory request failed.<br />

Action: Review the memory availability of the<br />

■ host TP system;<br />

■ host operating system; <strong>and</strong><br />

■ global common memory pool (BS2000 only; specified in the <strong>Adabas</strong> System<br />

Coordinator group definition).<br />

One of the following invalid values was used for a comm<strong>and</strong> ID value:<br />

■ X'00000000'<br />

■ X'40404040'<br />

Action: Do not use the above comm<strong>and</strong> ID values.<br />

Support for the use of this API has been withdrawn.<br />

Action: Please refer to the currently supported APIs or, alternatively, contact your<br />

<strong>Software</strong> <strong>AG</strong> technical support representative to discuss your requirements.<br />

An ET Data related comm<strong>and</strong> has been issued, but the runtime control ( see Database<br />

Number for ET Data, in the <strong>Adabas</strong> Vista Parameters manual) is not set to a specific<br />

database number <strong>and</strong> Vista has been unable to establish a target database to satisfy<br />

the comm<strong>and</strong>.<br />

Action: Review the runtime control Database Number for ET Data, in the <strong>Adabas</strong> Vista<br />

Parameters manual, to specifically identify the database number to be used.<br />

A sequence direction change has been detected during an L3 or L9 comm<strong>and</strong> against<br />

a Partitioned File whose Comm<strong>and</strong> ID sequence has been previously subjected to<br />

multifetch.<br />

Action: Review the program logic.<br />

An error has occurred during the processing of an L1 ‘get next’ comm<strong>and</strong> against<br />

a partitioned file.<br />

Action: Contact your <strong>Software</strong> <strong>AG</strong> technical support representative <strong>and</strong> use the COR<br />

Debug Event Monitor controls specifying Response 249 <strong>and</strong> this subcode to provide<br />

diagnostic information.<br />

The <strong>Adabas</strong> Vista database process is not installed. It must be installed on all <strong>Adabas</strong><br />

databases which contain <strong>Adabas</strong> Vista partitions. This subcode indicates that a<br />

database<br />

■ is not running with ADARUN VISTA=YES; or<br />

<strong>Adabas</strong> <strong>Transaction</strong> <strong>Manager</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong><br />

<strong>Adabas</strong> Response <strong>Codes</strong><br />

175

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!