Adabas Transaction Manager Messages and Codes - Software AG ...
Adabas Transaction Manager Messages and Codes - Software AG ...
Adabas Transaction Manager Messages and Codes - Software AG ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Adabas</strong> Response <strong>Codes</strong><br />
Response 65<br />
Origin<br />
Explanation<br />
Action<br />
Response 66<br />
Origin<br />
Explanation<br />
Action<br />
Response 67<br />
Origin<br />
Explanation<br />
Action<br />
Response 68<br />
Origin<br />
Explanation<br />
Action<br />
Response 70<br />
Origin<br />
Explanation<br />
Action<br />
94<br />
Mainframe systems only<br />
An internal error occurred. The nucleus detected a space calculation error.<br />
Contact your <strong>Software</strong> <strong>AG</strong> technical support representative for assistance.<br />
Mainframe systems only<br />
An incompatible owner ID was detected during an update operation on a multiclient file.<br />
The owner ID may be blank, or too long.<br />
Contact your <strong>Software</strong> <strong>AG</strong> technical support representative for assistance.<br />
Mainframe systems only<br />
One of the following errors occurred:<br />
Subcode Meaning<br />
.<br />
2<br />
An internal error occurred while executing an Sx comm<strong>and</strong>.<br />
An error occurred during superfield generation.<br />
Retain all related information, <strong>and</strong> contact your <strong>Software</strong> <strong>AG</strong> technical support representative<br />
for assistance.<br />
Mainframe systems only<br />
A nondescriptor field was used as a search criterion, <strong>and</strong> the non-descriptor search facility<br />
has been set OFF (the default for this facility is ON).<br />
The ADARUN parameter NONDES has been set to reject non-descriptor searches; either reset<br />
the NONDES parameter to its default value, or remove non-descriptor searches from your<br />
application. Natural provides a trace facility which locates such Natural application<br />
characteristics. Contact <strong>Software</strong> <strong>AG</strong> for details.<br />
Mainframe systems only<br />
An overflow occurred in the table of sequential comm<strong>and</strong>s.<br />
The DBA may increase the value used for the LQ parameter or RC comm<strong>and</strong>s may be used.<br />
<strong>Adabas</strong> <strong>Transaction</strong> <strong>Manager</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong>