<strong>Adabas</strong> Response <strong>Codes</strong><br />
Response 1<br />
Origin<br />
Mainframe <strong>and</strong> open systems<br />
Explanation The meaning of this response code varies, depending on whether you are using <strong>Adabas</strong> on<br />
mainframe systems or <strong>Adabas</strong> on open systems.<br />
Action<br />
48<br />
Mainframe Systems<br />
Depending on the subcode in the rightmost two bytes of the ACB's Additions 2 field or the<br />
ACBX's Error Subcode (ACBXERRC) field, one of the following has occurred:<br />
Subcode Meaning<br />
1<br />
2<br />
3<br />
4<br />
5<br />
An online SAVE operation cannot be executed without the nucleus' PLOG.<br />
The selected record is not allowed.<br />
S2 comm<strong>and</strong> did not have enough space.<br />
S2/S9 internal program error.<br />
System was not in save status at the end of an online ADASAV.<br />
Note: When one of the subcodes 2-4 is present, the cause could be an Sx comm<strong>and</strong> using<br />
security-by-value that found at least one ISN.<br />
Open Systems<br />
An ISN list could not be sorted as a result of an excessive number of resulting ISNs, or because<br />
during a non-descriptor search a value larger than the corresponding field length in the FDT<br />
was found, or because the ISN quantity returned does not correspond with the actual number<br />
of records found.<br />
For an S9 comm<strong>and</strong>, this response indicates that there is no space available for additional<br />
temporary working space. For an S2 comm<strong>and</strong>, this response is only a warning <strong>and</strong> the S2<br />
becomes an S1.<br />
The method of resolving the error varies, depending on whether you are using <strong>Adabas</strong> on<br />
mainframe systems or <strong>Adabas</strong> on open systems.<br />
Mainframe Systems<br />
Increase the ADARUN LS parameter value.<br />
Open Systems<br />
Provide sufficient disk space for temporary working space or adapt the FDT to the real field<br />
length.<br />
<strong>Adabas</strong> <strong>Transaction</strong> <strong>Manager</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong>