13.12.2012 Views

Adabas Transaction Manager Messages and Codes - Software AG ...

Adabas Transaction Manager Messages and Codes - Software AG ...

Adabas Transaction Manager Messages and Codes - Software AG ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Response 56<br />

Origin<br />

Explanation<br />

Action<br />

Response 57<br />

Origin<br />

Explanation<br />

Action<br />

Response 58<br />

Origin<br />

Explanation<br />

Action<br />

Response 59<br />

Origin<br />

Explanation<br />

Action<br />

Mainframe <strong>and</strong> open systems<br />

One of the following occurred:<br />

Subcode Meaning<br />

.<br />

n<br />

The descriptor value was too long.<br />

The collation value exceeded the maximum 253 bytes. The subcode n is the collation<br />

descriptor exit number.<br />

Store a shorter descriptor value or collation value.<br />

On open systems, you also can specify the TR option for the descriptor, which truncates larger<br />

descriptor values before they are stored in the index. Note that with the TR option, search<br />

results may be inaccurate: this is because values that are identical in the first 1144 bytes are<br />

considered to be equal to each other.<br />

Mainframe <strong>and</strong> open systems<br />

In an L9 comm<strong>and</strong>, the descriptor specified in the format or search buffer or in the Additions<br />

1 field was invalid or the descriptor was not specified:<br />

■ The field name specified may not be the name of a descriptor.<br />

■ The descriptor specified may be a phonetic descriptor or a hyperdescriptor, which are not<br />

allowed in an L9 comm<strong>and</strong>.<br />

■ On open systems, the descriptor specified may be a collation descriptor with the option<br />

HE.<br />

Correct the descriptor in the format buffer, search buffer, or Additions 1 field <strong>and</strong> try again.<br />

Mainframe systems only<br />

The format could not be found (as defined within format selection criteria).<br />

Adjust the format specification <strong>and</strong> try again.<br />

Mainframe systems only<br />

Format conversion of a subfield is not possible. The source field has fixed point (F) or floating<br />

point (G) format.<br />

Correct the field for which you are attempting format conversion <strong>and</strong> try again.<br />

<strong>Adabas</strong> <strong>Transaction</strong> <strong>Manager</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong><br />

<strong>Adabas</strong> Response <strong>Codes</strong><br />

89

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!