Action<br />

The following subcodes are possible:<br />

Subcode Meaning<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

1xx<br />

2xx<br />

Buffer length 0 (ACB user only)<br />

Format buffer address zero<br />

Record buffer address zero<br />

Search buffer address zero<br />

Value buffer address zero<br />

ISN buffer address zero<br />

User information buffer address zero<br />

Performance buffer address zero<br />

Multifetch buffer address zero<br />

Unsupported ABD buffer type<br />

Attached buffer overrun<br />

Unsupported ABD version<br />

ACBX not accepted by target<br />

Unable to convert ACBX to ACB<br />

ALET value not permitted<br />

Unable to process 64-bit buffer address<br />

Invalid buffer location indicator<br />

Logic error locating ABD<br />

More than 65,535 ABDs of any single type.<br />

Reserved field not zero<br />

ADABDX length incorrect<br />

An error occurred attempting to allocate a Pause Element. The subcode is 100<br />

(decimal) added to the return code from the z/OS IEAVAPE service.<br />

Action: Refer to IBM z/OS documentation for IEAVAPE for an explanation of its<br />

return code. Contact your <strong>Software</strong> <strong>AG</strong> support representative for assistance.<br />

An error occurred attempting to pause using a Pause Element. The subcode is 200<br />

(decimal) added to the return code from the z/OS IEAVPSE service.<br />

Action: Refer to IBM z/OS documentation for IEAVPSE for an explanation of its<br />

return code. Contact your <strong>Software</strong> <strong>AG</strong> support representative for assistance.<br />

On open systems, the system file is not loaded or inconsistent.<br />

For mainframe systems, subcodes 10 <strong>and</strong> 17 are internal logic errors; notify your <strong>Software</strong><br />

<strong>AG</strong> support representative. For all other subcodes, correct the buffer specification error <strong>and</strong><br />

rerun.<br />

On open systems, check the system files by running ADAVFY.<br />

<strong>Adabas</strong> <strong>Transaction</strong> <strong>Manager</strong> <strong>Messages</strong> <strong>and</strong> <strong>Codes</strong><br />