SET-UP MODE SUMMARY<br />
5.1 SET-UP MODE FUNCTIONS<br />
1. Sensor Type<br />
2. Probe Thermocouple Type<br />
3. Flue Thermocouple Type<br />
4. Transmitter Output Channel 1<br />
5. Transmitter Span Channel 1<br />
6. Transmitter Output Channel 2<br />
7. Transmitter Zero Channel 2<br />
8. Transmitter Span Channel 2<br />
9. Centigrade/Fahrenheit Selection<br />
10. Lower Line Display Functions<br />
11. Flue Pressure mm/inches/kilopascals<br />
12. Flue Pressure Value<br />
Set-up steps 13 to 27 will be skipped automatically if efficiency or oxygen deficiency are not selected in steps 6,<br />
10 or 46.<br />
13. Single or Dual Fuel<br />
14. Type of Fuel #1<br />
15. Fuel #1 ‘A’ Value<br />
16. Fuel #1 ‘H’ Value<br />
17. Fuel #1 ‘O’ Value<br />
18. Fuel #1 ‘N’ Value<br />
19. Fuel #1 ‘S’ Value<br />
20. Fuel #1 ‘M’ Value<br />
Set-up steps 21 to 27 will be skipped automatically if ‘Single Fuel’ is selected in set-up step 13. 21. Type of Fuel #2<br />
22. Fuel #2 ‘A’ Value<br />
23. Fuel #2 ‘H’ Value<br />
24. Fuel #2 ‘O’ Value<br />
25. Fuel #2 ‘N’ Value<br />
26. Fuel #2 ‘S’ Value<br />
27. Fuel #2 ‘M’ Value<br />
28. Purge/Cal Time<br />
29. Automatic Purge<br />
Set-up steps 30 to 32 will be skipped automatically if ‘No’ is selected in set-up step 29.<br />
30. Time Between Purges<br />
31. Purge Duration<br />
32. Purge Freeze Time<br />
33. Number of Cal Gases<br />
Set-up steps 34 to 45 may be skipped automatically, depending on the selection in set up step 33.<br />
34. Oxygen Content of Cal Gas 1<br />
35. Maximum Acceptable Positive Error Gas 1<br />
36. Maximum Acceptable Negative Error Gas 1<br />
37 Period Between Gas 1 Autocals<br />
38. Duration of Autocal Gas 1<br />
39. Freeze Time Gas 1<br />
40. Oxygen Content Of Cal Gas 2<br />
41. Maximum Acceptable Positive Error Gas 2<br />
42. Maximum Acceptable Negative Error Gas 2<br />
43. Period Between Gas 2 Autocals<br />
44. Duration of Autocal Gas 2<br />
45. Freeze Time Gas 2<br />
46. Data to Print<br />
47. Print Log Period<br />
48. Printer Baud Rate<br />
49. Relative Humidity Sensor Connected<br />
50. Switched Reference Air Supply<br />
51. Damping Factor<br />
NOVATECH <strong>OXYGEN</strong> ANALYSER 5.1