SET-UP MODE SUMMARY<br />

5.1 SET-UP MODE FUNCTIONS<br />

1. Sensor Type<br />

2. Probe Thermocouple Type<br />

3. Flue Thermocouple Type<br />

4. Transmitter Output Channel 1<br />

5. Transmitter Span Channel 1<br />

6. Transmitter Output Channel 2<br />

7. Transmitter Zero Channel 2<br />

8. Transmitter Span Channel 2<br />

9. Centigrade/Fahrenheit Selection<br />

10. Lower Line Display Functions<br />

11. Flue Pressure mm/inches/kilopascals<br />

12. Flue Pressure Value<br />

Set-up steps 13 to 27 will be skipped automatically if efficiency or oxygen deficiency are not selected in steps 6,<br />

10 or 46.<br />

13. Single or Dual Fuel<br />

14. Type of Fuel #1<br />

15. Fuel #1 ‘A’ Value<br />

16. Fuel #1 ‘H’ Value<br />

17. Fuel #1 ‘O’ Value<br />

18. Fuel #1 ‘N’ Value<br />

19. Fuel #1 ‘S’ Value<br />

20. Fuel #1 ‘M’ Value<br />

Set-up steps 21 to 27 will be skipped automatically if ‘Single Fuel’ is selected in set-up step 13. 21. Type of Fuel #2<br />

22. Fuel #2 ‘A’ Value<br />

23. Fuel #2 ‘H’ Value<br />

24. Fuel #2 ‘O’ Value<br />

25. Fuel #2 ‘N’ Value<br />

26. Fuel #2 ‘S’ Value<br />

27. Fuel #2 ‘M’ Value<br />

28. Purge/Cal Time<br />

29. Automatic Purge<br />

Set-up steps 30 to 32 will be skipped automatically if ‘No’ is selected in set-up step 29.<br />

30. Time Between Purges<br />

31. Purge Duration<br />

32. Purge Freeze Time<br />

33. Number of Cal Gases<br />

Set-up steps 34 to 45 may be skipped automatically, depending on the selection in set up step 33.<br />

34. Oxygen Content of Cal Gas 1<br />

35. Maximum Acceptable Positive Error Gas 1<br />

36. Maximum Acceptable Negative Error Gas 1<br />

37 Period Between Gas 1 Autocals<br />

38. Duration of Autocal Gas 1<br />

39. Freeze Time Gas 1<br />

40. Oxygen Content Of Cal Gas 2<br />

41. Maximum Acceptable Positive Error Gas 2<br />

42. Maximum Acceptable Negative Error Gas 2<br />

43. Period Between Gas 2 Autocals<br />

44. Duration of Autocal Gas 2<br />

45. Freeze Time Gas 2<br />

46. Data to Print<br />

47. Print Log Period<br />

48. Printer Baud Rate<br />

49. Relative Humidity Sensor Connected<br />

50. Switched Reference Air Supply<br />

51. Damping Factor<br />

NOVATECH <strong>OXYGEN</strong> ANALYSER 5.1