210| Dräger-<strong>Tubes</strong> for short-term measurements<br />

Application Range<br />

Standard Measuring Range: 5 to 50 ppm<br />

Number of Strokes n: 5<br />

Time for Measurement:<br />

approx. 1 min.<br />

Standard Deviation: ± 20 to 30 %<br />

Color Change:<br />

green ä brown<br />

Methyl Bromide 5/b<br />

Order No. CH 27 301<br />

Ambient Operating Conditions<br />

Temperature: 0 to 40 °C<br />

Absolute Humidity:<br />

3 to 15 mg H 2 O / L<br />

Reaction Principle<br />

a) CH 3 Br + SO 3 + MnO – 4 ä Br 2<br />

b) Br 2 + o-dianisidine ä brown reaction product<br />

Cross Sensitivity<br />

Other chlorinated hydrocarbons, free halogens and halogenated<br />

hydrocarbon acids are also indicated, however, with differing<br />

sensitivities.<br />