18.05.2018 Views

Tubes Handbook 18th Edition (EN) - May 2018

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

240| Dräger-<strong>Tubes</strong> for short-term measurements<br />

Phosphine 1/a<br />

Order No. 81 01 801<br />

Application Range<br />

Standard Measuring Range: 10 to 100 / 1 to 20 ppm<br />

Number of Strokes n: 2 / 10<br />

Time for Measurement:<br />

approx. 2 min / approx. 10 min<br />

Standard Deviation: ± 15 to 20 %<br />

Color Change:<br />

yellow ä dark-brown<br />

Ambient Operating Conditions<br />

Temperature: 5 to 40 °C<br />

Absolute Humidity:<br />

max. 30 mg H 2 O / L<br />

Reaction Principle<br />

PH 3 + Au 3+ ä Au (colloidal)<br />

Cross Sensitivity<br />

Ammonia, hydrogen chloride, hydrogen sulfide and mercaptans<br />

are retained in the prelayer. Arsine and stibine are also indicated,<br />

however, with less sensitivity.<br />

ST-111-2001

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!