You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
|57<br />
A<br />
The Dräger Flow Check incorporates ergonomic form,<br />
low weight, and optimal operation into the instrument<br />
design. The instrument will generate clouds in any<br />
orientation.<br />
ST-61-98<br />
Small, single clouds can be generated with a short press of a button. If a continous<br />
production of clouds is desired, the button can be held or locked in the “on” position. The<br />
fluid ampoule is located in a compartment in the handle of the instrument and can be<br />
inserted effortlessly into position. The amount of fluid contained in the ampoule is enough<br />
to generate approximately five minutes.<br />
Power is supplied by a battery located in the handle of the<br />
instrument and can be charged while inside the instrument or<br />
separately. A quickcharge option is also possible with the<br />
charger. An adapter cable can be used to charge the device from<br />
a car mounted cigarette lighter.<br />
ST-64-98<br />
Dräger Flow Check<br />
2.13 Dräger-Measurement-Systems for Long-term<br />
Measurements<br />
The Dräger diffusion tubes are direct reading systems used for the determination of time<br />
weighted average concentrations over the duration of one to eight hours. Since these are<br />
passive measurement systems, relying on the diffusion of contaminant molecules in air, they<br />
do not require a pump. The diffusion tubes are used with a plastic holder which is attached<br />
to the clothing (shirt collar, pocket, etc.).<br />
The scale printed on the diffusion tube represents the<br />
product of the concentration and exposure time given e.<br />
g. as ppm x h, ppm x min, Vol.-% x h or mg/L x h. To<br />
determine the average concentration of the contaminant,<br />
the scale reading is divided by the exposure time (i. e.<br />
sampling time) according to the following:<br />
c =<br />
indication in ppm · h<br />
time in h<br />
[ppm]<br />
Dräger-Diffusion-<strong>Tubes</strong> with direct<br />
indication<br />
ST-1350-2004