26.12.2012 Views

Distribution of Chlorinated Hydrocarbon Pesticides and PCBs in the ...

Distribution of Chlorinated Hydrocarbon Pesticides and PCBs in the ...

Distribution of Chlorinated Hydrocarbon Pesticides and PCBs in the ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

cleaned. Samples were collected on 8 cm. x 11 cm. teflon<br />

re<strong>in</strong>forced glass fibre (May, 1986, solvent r<strong>in</strong>sed) or cellulose<br />

(August, 1986, soxhlet extracted with acetone) filters. Flow<br />

rates were measured <strong>and</strong> recorded on a clock driven rotat<strong>in</strong>g card<br />

recorder which also provided a record <strong>of</strong> <strong>the</strong> length <strong>of</strong> <strong>the</strong><br />

sampl<strong>in</strong>g period.<br />

Air samples were collected for a period <strong>of</strong> from 30 to 52 h<br />

at a flow rate <strong>of</strong> from 1.62 to 1.67 m3*m<strong>in</strong>-l. Dur<strong>in</strong>g operation,<br />

<strong>the</strong> sampler was approached from <strong>the</strong> downw<strong>in</strong>d direction <strong>and</strong>, when<br />

necessary, <strong>the</strong> power generator relocated to be downw<strong>in</strong>d <strong>of</strong> <strong>the</strong><br />

sampler. At <strong>the</strong> end <strong>of</strong> <strong>the</strong> sampl<strong>in</strong>g period, <strong>the</strong> filter was<br />

folded us<strong>in</strong>g solvent clean tongs so as to reta<strong>in</strong> collected<br />

particulates. It was found necessary to do this while <strong>the</strong> filter<br />

rema<strong>in</strong>ed <strong>in</strong> <strong>the</strong> sampler with <strong>the</strong> pump <strong>in</strong> operation to avoid loss<br />

<strong>of</strong> <strong>the</strong> filter due to <strong>the</strong> w<strong>in</strong>d. The filters were stored <strong>in</strong><br />

prebaked alum<strong>in</strong>um foil pouches <strong>and</strong> were stored frozen.<br />

2.8.2 Va~our Phase ~am~l<strong>in</strong>q<br />

Two <strong>in</strong>dependent but similar systems, <strong>the</strong> Arctic Labs High<br />

Volume Sampler (AHVS) <strong>and</strong> Terry Bidleman High Volume Sampler<br />

(TBHVS) were used to collect vapour phase chlor<strong>in</strong>ated organics.<br />

Both employed polyurethane foam plugs to reta<strong>in</strong> <strong>the</strong> sample, but<br />

differed <strong>in</strong> mechanical details.<br />

The results <strong>of</strong> <strong>the</strong> 1986 air sampl<strong>in</strong>g with <strong>the</strong> AHVS<br />

<strong>in</strong>dicated that some channel<strong>in</strong>g around <strong>the</strong> front polyurethane plug<br />

had occured, presumably due to shr<strong>in</strong>kage dur<strong>in</strong>g sampl<strong>in</strong>g.<br />

Subsequently , <strong>in</strong> 1987 a redesigned one piece f ilter/plug holder<br />

was used similar to that used <strong>in</strong> <strong>the</strong> TBHVS air sampler.<br />

The AHVS is shown <strong>in</strong> Figure 2.2 <strong>and</strong> consisted <strong>of</strong> a 142 mm<br />

sta<strong>in</strong>less steel filter unit, a pair <strong>of</strong> poly-urethane foam plugs<br />

(15 cm x 7.8 cm) <strong>in</strong> a holder, a calibrated flowmeter <strong>and</strong> high<br />

capacity oil-less vane pump (Gast, 270 L/m<strong>in</strong>ute) driven by a<br />

brushless motor. The sampler was situated 4 m up w<strong>in</strong>d <strong>of</strong> <strong>the</strong> air<br />

pump <strong>and</strong> was approached from down w<strong>in</strong>d when <strong>in</strong> use.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!