Errata A<br />

<strong>Comtech</strong> <strong>EF</strong><strong>Data</strong> Documentation Update<br />

Subject: Changes to Chapter 3 (Communications Link Jumper Setting)<br />

Date: July 28, 1997<br />

Document: <strong>RSU</strong>-<strong>503</strong> <strong>Redundancy</strong> <strong>Switch</strong> <strong>Unit</strong> <strong>Installation</strong> and Operation<br />

Manual, Rev. 8, dated April 4, 1997<br />

Part Number: MN/<strong>RSU</strong><strong>503</strong>.EA8<br />

Collating Instructions: Attach this page to page 3-1<br />

Comments:<br />

The following changes provide the correct information for jumper placement when choosing<br />

between RS-232 or -485. This information will be incorporated into the next revision.<br />

Change Specifics:<br />

3.4.1 Communications Link<br />

The terminal functions can be remotely controlled and monitored via an RS-485 or RS-232<br />

communications link.<br />

• The RS-485 interface makes it possible to operate 255 terminals on a common communications<br />

link.<br />

• The RS-232 interface is used to communicate with a single terminal.<br />

The M&C module must be hardware configured on the M&C board to one of the two interfaces. Refer to<br />

the following table for jumper placement at JP1:<br />

RS-485<br />

Configuration<br />

RS-232<br />

Configuration<br />

1-2 9-10<br />

3-4 11-12<br />

5-6 13-14<br />

7-8 15-16<br />