RSU-503 Redundancy Switch Unit RSU-503L Option A.5 Addressing Table A-2. Waveguide Switch Cable Dimensions Dimension “A” Dimension “B” 12 ft. 10 ft. 17 ft. 15 ft. 22 ft. 20 ft. The following are the factory default addresses: • RSU-503 is set to address 1 • RFT A is set to address 2 • RFT B is set to address 3 The proper M&C cable hook-up is critical: • RFT A must be connected to the RSU Port A • RFT B must be connected to the RSU Port B Note: If these connections are reversed, no communications will take place. Rev. 8 A–7

RSU-503L Option RSU-503 Redundancy Switch Unit This page is intentionally left blank. A–8 Rev. 8