<strong>Installation</strong> <strong>RSU</strong>-<strong>503</strong> <strong>Redundancy</strong> <strong>Switch</strong> <strong>Unit</strong><br />

2.4.6.2 LNA Plate to Waveguide <strong>Switch</strong><br />

The following table outlines the pinouts of the LNA plate to Waveguide <strong>Switch</strong> cable.<br />

This cable is internal on the redundant LNA plate.<br />

Note: This pinout table may be helpful if an <strong>EF</strong><strong>Data</strong> Waveguide <strong>Switch</strong> is used.<br />

Name Pin # Function<br />

Command, Position 1 A +28V pulse for 500 milliseconds<br />

Command Common B Ground<br />

Command, Position 2 C +28V pulse for 500 milliseconds<br />

Indicator, Position 1 D Connects to Common when in position 1<br />

Indicator Common E Ground<br />

Indicator, Position 2 F Connects to Common when in position 2<br />

2.4.7 TX/RF Output (J11)<br />

The TX/RF Output connector is a 50Ω type N connector used to monitor the transmit<br />

output signal from the offline RFT. This connector is used to test the offline unit.<br />

2.4.8 TX/IF Input (J12)<br />

The TX/IF Input connector is a 50Ω TNC connector used to input the IF test signal to the<br />

offline RFT. This connector is used to test the offline unit.<br />

2.4.9 RX/IF Output (J13)<br />

The RX/IF Output connector is a 50Ω TNC connector used to monitor the IF output<br />

signal from the offline RFT. This connector is used to test the offline unit.<br />

2.4.10 TX/IF Input (J14)<br />

The TX/IF Input connector is a 50Ω TNC connector used to receive the IF uplink signal<br />

from the modem. The switch routes the signal to the online RFT for transmission.<br />

2.4.11 RX/IF Output (J15)<br />

The RX/IF Output connector is a 50Ω TNC connector used to provide the IF downlink<br />

signal to the modem (after the signal is picked up by the antenna and routed through the<br />

online LNA and RFT).<br />