03.01.2013 Views

alpha bs

alpha bs

alpha bs

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

312<br />

Electronic control<br />

equipment<br />

Product Article-No. Order-No. Pack/Qty<br />

Busch-Dimmer ®<br />

Complete unit in SI design<br />

with leading edge control<br />

For incandescent lamps and 230 V tungsten halogen lamps.<br />

Rated voltage: 230 V~, +10 % / -10 %<br />

Rated frequency: 50 Hz<br />

Rated power: 60 - 400 W<br />

IEC 60669-2-1, British Standard EN 60669-2-1 1 )<br />

212 white 2200 UJ-212 6514-0-0012 1/10<br />

Cover plate for rotary dimmer 2200 UJ-212, for combinations<br />

212 white 2110 C -212 1717-0-0065 10<br />

1) Non-illuminable.<br />

Busch-Rotary switch dimmer insert 1 )<br />

For use in 2 gang connections<br />

1 channel designed as dimmer.<br />

1 channel designed as switch contact (1-gang 2-way<br />

contact element)<br />

with leading edge control<br />

For incandescent lamps, 230 V tungsten halogen lamps<br />

and low-volt halogen lamps with conventional transformer.<br />

With adjustable minimum brightness.<br />

Without cover plate.<br />

Rated current 6A (changeover contact switch output).<br />

Rated voltage: 230 V~, +10 % / -10 %<br />

Rated frequency: 50 Hz<br />

Rated power: 60 - 400 W/VA<br />

IEC 60669-2-1, British Standard EN 60669-2-1<br />

6517 U-1 01-500 6517-0-0018 1/10<br />

1) In the case of conventional transformers, take ~20% transformer loss into account.<br />

Busch Memory 2gang Dimmer 1 ) 2 )<br />

For use in 2 gang connections<br />

For switching and dimming 2 independent devices.<br />

With trailing edge control.<br />

2gang 1way<br />

For incandescent lamps, 230 V tungsten halogen lamps<br />

and low-voltage halogen lamps with electronic transformers.<br />

Compatible with control covers 6545-xxx.<br />

without cover, without cover plate<br />

Outputs: 2 independent dimmer channels.<br />

Rated power: 40-315 W/VA per channel.<br />

Rated voltage: 230 V~, +10 % / -10 %<br />

Rated frequency: 50 Hz/60 Hz<br />

IEC 60669-2-1, British Standard EN 60669-2-1<br />

6565 U-50 0 6565-0-0057 1/10<br />

1) Not suitable with conventional transformers.<br />

2) In case of electronic transformers, 5 % transformer losses.<br />

Busch-Dimmer ® inser t 1 ) 2 ) 3 )<br />

With rotary control, 2way On-Off switching and soft-catch.<br />

Leading Edge control.<br />

For incandescent lamps and 230 V tungsten halogen<br />

lamps.<br />

With adjustable minimum brightness.<br />

Without cover plate.<br />

Rated voltage: 230 V~, +10 % / -10 %<br />

Rated frequency: 50 Hz<br />

Rated power: 60 - 600 W<br />

IEC 60669-2-1, British Standard EN 60669-2-1<br />

2250 U 6515-0-0704 1/10<br />

1) Illuminable with neon lamp. Neon lamp included in delivery with cover plate.<br />

2) Also applicable for 1gang 2way installations.<br />

3 ) Provided with terminal for net disconnection devices.<br />

Technical information<br />

www.BUSCH-JAEGER-catalogue.com<br />

Product Article-No. Order-No. Pack/Qty<br />

Busch-Dimmer ® insert 1 ) 2 ) 3 ) 4 )<br />

With rotary control, 2way On-Off switching and soft-catch.<br />

Leading Edge control.<br />

For incandescent lamps, 230 V tungsten halogen lamps<br />

and low-volt halogen lamps with conventional transformer.<br />

With adjustable minimum brightness.<br />

Without cover plate.<br />

Rated voltage: 230 V~, +10 % / -10 %<br />

Rated frequency: 50 Hz<br />

Rated power: 20 - 500 W/VA<br />

IEC 60669-2-1, British Standard EN 60669-2-1<br />

2247 U-500 6512-0-0302 1/10<br />

1) Illuminable with neon lamp. Neon lamp included in delivery with cover plate.<br />

2) In the case of conventional transformers, take ~20% transformer loss into account.<br />

3) Provided with terminal for net disconnection devices.<br />

4) Also applicable for 1gang 2way installations.<br />

Busch-Dimmer ® insert 1 ) 2 ) 3 ) 4 )<br />

With rotary control, soft-catch and with leading edge<br />

control.<br />

For switching and dimming incandescent lamps, 230 V<br />

tungsten halogen lamps and low-voltage halogen lamps<br />

with conventional transformer.<br />

Without cover plate.<br />

With adjustable minimum brightness.<br />

Rated voltage: 127 V~<br />

Rated frequency: 60 Hz<br />

Rated power: 20 - 250 W<br />

IEC 60669-2-1, British Standard EN 60669-2-1<br />

2247 U-127 6512-0-0297 1/10<br />

1) Illuminable with neon lamp. Neon lamp included in delivery with cover plate.<br />

2) In the case of conventional transformers, take ~20% transformer loss into account.<br />

3) Provided with terminal for net disconnection devices.<br />

4) Also applicable for 1gang 2way installations.<br />

Busch-Dimmer ® insert 1 ) 2 ) 3 ) 4 ) 5 )<br />

With rotary control, 2way On-Off switching, and softcatch;<br />

trailing edge control.<br />

For incandescent lamps, 230 V tungsten halogen lamps<br />

and low-voltage halogen lamps with electronic transformers.<br />

Low-noise, short-circuit protected, overload-protected.<br />

Without cover plate.<br />

Rated voltage: 230 V~, +10 % / -10 %<br />

Rated frequency: 50 Hz<br />

Rated power: 40 - 420 W/VA<br />

IEC 60669-2-1, British Standard EN 60669-2-1<br />

6513 U-102-500 6513-0-0586 1/10<br />

1) Not suitable with conventional transformers.<br />

2) Illuminable with neon lamp. Neon lamp included in delivery with cover plate.<br />

3) In case of electronic transformers, 5 % transformer losses.<br />

4) Provided with terminal for net disconnection devices.<br />

5) Also applicable for 1gang 2way installations.<br />

Busch-Dimmer ® insert 1 ) 2 ) 3 ) 4 ) 5 )<br />

With rotary control, 2way On-Off switching, and softcatch;<br />

trailing edge control.<br />

For incandescent lamps, 230 V tungsten halogen lamps and<br />

low-voltage halogen lamps with electronic transformers.<br />

Low-noise, short-circuit protected, overload-protected.<br />

Without cover plate.<br />

Rated voltage: 230 V~, +10 % / -10 %<br />

Rated frequency: 50 Hz<br />

Rated power: 40 - 550 W/VA<br />

IEC 60669-2-1, British Standard EN 60669-2-1<br />

6519 U 6519-0-0011 1<br />

1) Not suitable with conventional transformers.<br />

2) Illuminable with neon lamp. Neon lamp included in delivery with cover plate.<br />

3) In case of electronic transformers, 5 % transformer losses.<br />

4) Provided with terminal for net disconnection devices.<br />

5) Also applicable for 1gang 2way installations.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!