454<br />

ABB i-bus ® KNX<br />

Product Article-No. Order-No. Pack/Qty<br />

Choke<br />

SELV<br />

The choke disconnects the bus line from the power<br />

supply. It can be used to supply a second KNX line in<br />

combination with the SV/S 30.640.5 power supply.<br />

The choke has a reset button to release the bus line and<br />

reset the bus su<strong>bs</strong>cribers connected to this line to the<br />

initial state.<br />

The bus connection is made via a bus terminal.<br />

The 30V auxiliary voltage is connected via a connecting<br />

terminal.<br />

Control element: Reset switch<br />

Display elements: Operating LED<br />

Connections:<br />

KNX-line: integrated pressure contacts<br />

Rated voltage: 30 V<br />

Outputs: 1<br />

Supply voltage: 29 V<br />

Rated current: 500 mA<br />

Protection class (Device): IP 20<br />

Temperature range (Device): -5 °C to 45 °C<br />

Dimensions: (L x W x D): 90 mm x 36 mm x 64 mm<br />

module width: 2 MW<br />

DR/S 4.1 2CDG110029R0011<br />

Interface USB 1 ) 2 ) 3 )<br />

The USB/S 1.1 USB interface enables communication<br />

between the computer and the KNX system.<br />

The data transfer is displayed using the KNX and USB<br />

LEDs.<br />

The USB interface can be used from ETS 3 V1.0 on.<br />

Display elements: LED T: message interchange on the<br />

bus,<br />

LED K: communication via the interface<br />

Connections:<br />

KNX-line: Bus terminal<br />

Protection class (Device): IP 20<br />

Temperature range (Device): -5 °C to 45 °C<br />

Dimensions: (L x W x D): 90 mm x 36 mm x 61 mm<br />

Installation depth: 68 mm<br />

module width: 2 MW<br />

USB/S 1 .1 2CDG110008R0011<br />

1) As required, you can fi nd the programmable functions in the current application description, which<br />

you can download in the Support Centre on our Internet page.<br />

2) 1 MW 18 mm.<br />

3) Use only in combination with the ETS 3 or PowerProjekt 4.0<br />

Interface RS-232 1 ) 2 )<br />

2gang<br />

For coupling a PC or printer to the KNX data bus.<br />

The device can be used both to parameterise a KNX installation<br />

and to log events (fault messages) on a printer.<br />

Display elements: LED T: Message interchange to the bus,<br />

LED K: Protocolling and parameterising the communication<br />

via the interface<br />

Connections:<br />

KNX-line: Bus terminal<br />

Protection class (Device): IP 20<br />

Temperature range (Device): -5 °C to 45 °C<br />

Dimensions: (L x W x D): 90 mm x 36 mm x 61 mm<br />

Installation depth: 68 mm<br />

module width: 2 MW<br />

EA/S 232.5 GHQ6310043R0111<br />

1) As required, you can fi nd the programmable functions in the current application description, which<br />

you can download in the Support Centre on our Internet page.<br />

2) 1 MW 18 mm.<br />

Technical information<br />

www.BUSCH-JAEGER-catalogue.com<br />

Product Article-No. Order-No. Pack/Qty<br />

1) ETS programming only from ETS 2 V1.2.<br />

1) 1 MW 18 mm.<br />

1) 1 MW 18 mm.<br />

Line coupler 1 )<br />

The line coupler is used to connect KNX lines or areas<br />

in larger installations. In the process, the lines/areas are<br />

galvanically isolated from each other. At the same time,<br />

telegrams can be fi ltered to reduce the telegram traffi c<br />

in a line.<br />

The LK/S 4.1 has bus connecting terminals for the main<br />

line and subordinate lines.<br />

Within a line, the LK/S 4.1 can also be used as a line<br />

amplifi er (repeater).<br />

Display elements: LEDs: Voltage monitoring, message<br />

interchange<br />

Connections:<br />

higher-ranking line: Bus terminal<br />

lower-ranking line: Bus connection terminal<br />

Rated voltage: 29 V<br />

Protection class (Device): IP 20<br />

Temperature range (Device): -5 °C to 45 °C<br />

Dimensions: (L x W x D): 90 mm x 18 mm x 61 mm<br />

Installation depth: 68 mm<br />

module width: 2 MW<br />

LK/S 4.1 2CDG110027R0011<br />

IP router 1 )<br />

The IP router is the interface between KNX installations<br />

and IP networks. It can be used as a fast line or area<br />

coupler and thus as a local area network (LAN) for the fast<br />

exchange of telegrams between the lines/areas. With ETS<br />

3.0, KNX devices can be programmed via LAN. The device<br />

uses the KNXnet/IP protocol of the KNX association<br />

(routing and tunnelling). The IP address of the IG/S can<br />

be permanently assigned or received by a DHCP server.<br />

Power is supplied via 12 to 30 V DC.<br />

Dimensions: (L x W x D): 90 mm x 36 mm x 64 mm<br />

Installation depth: 68 mm<br />

module width: 2 MW<br />

IPR/S 2.1 2CDG110061R0011<br />

IP interface 1 )<br />

Interface between KNX and IP networks for the programming<br />

of KNX devices together with ETS 3.0 or for forwarding<br />

telegrams to/from the LAN (e.g. for visualisations).<br />

The device uses the KNXnet/IP protocol of the KNX association<br />

(tunnelling). The IP address can be permanently<br />

assigned or received by a DHCP server. Power is supplied<br />

via 12 to 30 V DC.<br />

Dimensions: (L x W x D): 90 mm x 36 mm x 64 mm<br />

Installation depth: 68 mm<br />

module width: 2 MW<br />

IPS/S 2.1 2CDG110098R0011<br />

Optical fi ber interface<br />

The device is used to connect two sections of an ABB<br />

i-bus ® KNX line using optical fi ber link to bridge greater<br />

distances or avoid having to use lightening and overvoltage<br />

protection devices when laying lines beyond the<br />

building.<br />

Two devices are required to set up a transmission route.<br />

Control element: Send/receive LED<br />

Connections:<br />

KNX-line: Bus terminal<br />

Protection class (Device): IP 20<br />

module width: 4 MW<br />

LL/S 1.1 GHQ6050053R0001