444<br />

ABB i-bus ® KNX<br />

Product Article-No. Order-No. Pack/Qty<br />

Switch actuator, 10 AX 1 ) 2 )<br />

12gang<br />

Switches 12 independent electrical loads via ABB i-bus ®<br />

KNX with fl oating contacts.<br />

For each output, the contact can be manually operated.<br />

The switching state of the contact is displayed.<br />

The 10AX-AC1 series is suited for switching ohmic, inductive,<br />

and capacitive loads, as well as fl uorescent lamp<br />

loads (AX) according to DIN EN 60669.<br />

Control element: Manual operation possibility for ON/OFF<br />

via sliding switch<br />

Connections:<br />

KNX-line: Bus terminal<br />

Rated voltage: 230 V~, +10 % / -15 %<br />

Rated frequency: 50 Hz/60 Hz<br />

Outputs: 12x Normally open contact, potential free<br />

Suitable for: AC1<br />

Rated current: 10 A, cos 1<br />

Protection class (Device): IP 20<br />

Temperature range (Device): -5 °C to 45 °C<br />

Dimensions: (L x W x D): 90 mm x 216 mm x 64 mm<br />

Installation depth: 68 mm<br />

module width: 12 MW<br />

SA/S 12.1 0.1 2CDG110042R0011<br />

1) As required, you can fi nd the programmable functions in the current application description, which<br />

you can download in the Support Centre on our Internet page.<br />

2) 1 MW 18 mm.<br />

Switch actuator, 16 A, C-load 1 ) 2 )<br />

12gang<br />

Switches 12 independent electrical loads via ABB i-bus ®<br />

KNX with fl oating contacts. For each output, the contact<br />

can be manually operated. The switching state of the<br />

contact is displayed. The 16A-AC1 series is suited for<br />

switching ohmic, inductive, and capacitive loads.<br />

Control element: Manual operation possibility for ON/OFF<br />

via sliding switch<br />

Display elements: Status display of the outputs via position<br />

of the sliding switches<br />

Connections:<br />

KNX-line: Bus terminal<br />

Rated voltage: 230 V~, +10 % / -15 %<br />

Rated frequency: 50 Hz/60 Hz<br />

Outputs: 12x Normally open contact, potential free<br />

Suitable for: AC1<br />

Rated current: 16 A, cos 1<br />

Output voltage: 230 V~<br />

Suitable for: AC3<br />

Rated current: 10 A, cos 0.65<br />

Output voltage: 230 V~<br />

Suitable for: AC3<br />

Rated current: 6 A, cos 0.65<br />

Output voltage: 400 V~<br />

Protection class (Device): IP 20<br />

Temperature range (Device): -5 °C to 45 °C<br />

Dimensions: (L x W x D): 90 mm x 216 mm x 64 mm<br />

Installation depth: 68 mm<br />

module width: 12 MW<br />

SA/S 12.16.1 2CDG110082R0011<br />

1) As required, you can fi nd the programmable functions in the current application description, which<br />

you can download in the Support Centre on our Internet page.<br />

2) 1 MW 18 mm.<br />

Technical information<br />

www.BUSCH-JAEGER-catalogue.com<br />

Product Article-No. Order-No. Pack/Qty<br />

Switch actuator, 16 AX 1 ) 2 )<br />

12-gang, C-load<br />

Switches 12 independent electrical loads via ABB i-bus ®<br />

KNX with fl oating contacts.<br />

For each output, the contact can be manually operated.<br />

The 16AX-AC3 C-load series is particularly suited for<br />

switchings loads with high switch-on current peaks like<br />

lamps with compensation capacitors or fl uorescent lamp<br />

loads (AX) according to DIN EN 60669.<br />

Control element: Manual operation possibility for ON/OFF<br />

via sliding switch<br />

Display elements: Status display of the outputs via position<br />

of the sliding switches<br />

Connections:<br />

KNX-line: Bus terminal<br />

Rated voltage: 230 V~, +10 % / -15 %<br />

Rated frequency: 50 Hz/60 Hz<br />

Outputs: 12x Normally open contact, potential free<br />

Suitable for: AC1<br />

Rated current: 16 A, cos 1<br />

Output voltage: 230 V~<br />

Suitable for: AC3<br />

Rated current: 10 A, cos 0.65<br />

Output voltage: 230 V~<br />

Suitable for: AC3<br />

Rated current: 6 A, cos 0.65<br />

Output voltage: 400 V~<br />

Protection class (Device): IP 20<br />

Temperature range (Device): -5 °C to 45 °C<br />

Dimensions: (L x W x D): 90 mm x 216 mm x 64 mm<br />

Installation depth: 68 mm<br />

module width: 12 MW<br />

SA/S 12.16.5 2CDG110046R0011<br />

1) As required, you can fi nd the programmable functions in the current application description, which<br />

you can download in the Support Centre on our Internet page.<br />

2) 1 MW 18 mm.<br />

Switch actuator, 20 AX 1 ) 2 )<br />

12-gang, C-load<br />

Switches 12 independent electrical loads via ABB i-bus ®<br />

KNX with fl oating contacts.<br />

For each output, the contact can be manually operated.<br />

The 20AX-AC3 C-load series is particularly suited for<br />

switchings loads with high switch-on current peaks like<br />

lamps with compensation capacitors or fl uorescent lamp<br />

loads (AX) according to DIN EN 60669.<br />

Control element: Manual operation possibility for ON/OFF<br />

via sliding switch<br />

Display elements: Status display of the outputs via position<br />

of the sliding switches<br />

Connections:<br />

KNX-line: Bus terminal<br />

Rated voltage: 230 V~, +10 % / -15 %<br />

Rated frequency: 50 Hz/60 Hz<br />

Outputs: 12x Normally open contact, potential free<br />

Suitable for: AC1<br />

Rated current: 20 A, cos 0.8<br />

Output voltage: 230 V~<br />

Suitable for: AC3<br />

Rated current: 16 A, cos 0.45<br />

Output voltage: 230 V~<br />

Protection class (Device): IP 20<br />

Temperature range (Device): -5 °C to 45 °C<br />

Dimensions: (L x W x D): 90 mm x 216 mm x 64 mm<br />

Installation depth: 68 mm<br />

module width: 12 MW<br />

SA/S 12.20.1 2CDG110050R0011<br />

1) As required, you can fi nd the programmable functions in the current application description, which<br />

you can download in the Support Centre on our Internet page.<br />

2) 1 MW 18 mm.