428<br />

ABB i-bus ® KNX<br />

Product Article-No. Order-No. Pack/Qty<br />

KNX universal interface 1 )<br />

2gang<br />

The universal interface has 2 channels. These channels<br />

can be parameterised as an input or output using ETS.<br />

Conventional push-switches, auxiliary contacts, luminous<br />

diodes, and the ER/U electrical relay can be connected to<br />

the connecting lines. These lines can be extended up to<br />

10 m.<br />

The contact scanning voltage and the feed voltage for the<br />

LEDs are provided by the device, and the series resistors<br />

for the LEDs are integrated.<br />

Connections:<br />

KNX-line: Bus terminal<br />

Inputs: 2<br />

Polling voltage: 20 V<br />

Outputs: 2x electronic output, potential-bound<br />

Supply voltage: 5 V<br />

Rated current: 2 mA<br />

Protection class (Device): IP 20<br />

Temperature range (Device): -5 °C to 45 °C<br />

Dimensions: (L x W x D): 39 mm x 40 mm x 12 mm<br />

US/U 2.2 GHQ6310074R0111<br />

1) As required, you can fi nd the programmable functions in the current application description, which<br />

you can download in the Support Centre on our Internet page.<br />

KNX universal interface 1 )<br />

4gang<br />

The universal interface has 4 channels. These channels<br />

can be parameterised as an input or output using ETS.<br />

Conventional push-switches, auxiliary contacts, luminous<br />

diodes, and the ER/U electrical relay can be connected to<br />

the connecting lines. These lines can be extended up to<br />

10 m.<br />

The contact scanning voltage and the feed voltage for the<br />

LEDs are provided by the device, and the series resistors<br />

for the LEDs are integrated.<br />

Connections:<br />

KNX-line: Bus terminal<br />

Inputs: 4<br />

Polling voltage: 20 V<br />

Outputs: 2x electronic output, potential-bound<br />

Rated current: 2 mA<br />

Protection class (Device): IP 20<br />

Temperature range (Device): -5 °C to 45 °C<br />

Dimensions: (L x W x D): 39 mm x 40 mm x 12 mm<br />

US/U 4.2 GHQ6310070R0111<br />

1) As required, you can fi nd the programmable functions in the current application description, which<br />

you can download in the Support Centre on our Internet page.<br />

Technical information<br />

www.BUSCH-JAEGER-catalogue.com<br />

Product Article-No. Order-No. Pack/Qty<br />

Universal interface<br />

12gang<br />

The device has 12 channels that can be parameterised as<br />

individually as inputs or outputs through selection in the<br />

application program.<br />

Convention push-switches, fl oating contacts, or luminous<br />

diodes can be connected.<br />

The contact scanning voltage of the contacts and the feed<br />

voltage for the LEDs are provided by the device.<br />

Series resistors for external luminous diodes are installed<br />

in the device.<br />

The universal interface is installed into a device connecting<br />

socket, 60 mm, in a fl ush-mounted manner.<br />

The following functions can be set according to input:-<br />

Any reaction to an edge at the output- Sending of switch/<br />

dimmer commands- Operation of dimmable lighting via a<br />

single push-switch- Operation of blinds via a single pushswitch-<br />

Control and saving of light scenes- Sending any<br />

values to data types- Switching of several loads in fi xed<br />

switching sequences- Generation of a PWM signal for a<br />

heating control system- Switching and fl ashing of LEDs.<br />

Channels: 12, can be parameterised individually as input<br />

or output; output scanning voltage: 20 V pulses; input current:<br />

0.5 mA; output voltage of output: 3.3 V DC; output<br />

current: max. 2 mA, limited via series resistor; connection<br />

of inputs/outputs: 3x6 lines, approx. 30 cm long, pluggable,<br />

extendable to a maximum of 10 m; bus connection:<br />

bus connecting terminal; dimensions (dia. x H): 54 x 19<br />

mm; degree of protection: IP 20, EN 60529.<br />

US/U 12.2 2CDG110065R0011<br />

Heating actuator 1 )<br />

1-gang actuator<br />

1 electronic output (noiseless)<br />

For connecting the thermoelectric valve drives TSA/K<br />

230.1 or TSA/K 24.1<br />

Per channel a maximum of 5 positioners can be connected<br />

in parallel<br />

2 inputs for potential free contacts<br />

Connecting cables max. 10 m<br />

The bus connection is effected via the enclosed bus<br />

terminal.<br />

Connections:<br />

KNX-line: Bus terminal<br />

Rated voltage: 230 V~, +10 % / -10 %<br />

Output voltage: 24 V~<br />

Rated frequency: 50 Hz<br />

Outputs: 1x electronic output, potential free<br />

Suitable for: AC1<br />

Rated current: 1 A, cos 1<br />

Protection class (Device): IP 20<br />

Temperature range (Device): -25 °C to 60 °C<br />

Dimensions: (L x W x D): 53 mm x 52 mm x 24 mm<br />

6164 U-500 6151-0-0168 1/10<br />

1) As required, you can fi nd the programmable functions in the current application description, which<br />

you can download in the Support Centre on our Internet page.