ABB i-bus ® KNX<br />

Product Article-No. Order-No. Pack/Qty<br />

1) 1 MW 18 mm.<br />

1) 1 MW 18 mm.<br />

*) Phase-out t ype<br />

Bolt switch contact<br />

For installation into a face plate, used to monitor the<br />

closure of doors.<br />

Watertight IP 67<br />

With LIVY 3 x 0.14 mm² 2.5 m connecting cable.<br />

WRK/W<br />

Technical information<br />

www.BUSCH-JAEGER-catalogue.com<br />

GH-<br />

V9250022V0005<br />

Lock monitoring for windows<br />

The closure is monitored using a special magnet and a<br />

reed contact.<br />

The magnet is installed onto the push rod of the window<br />

sash, and the reed contact is mounted on the frame.<br />

The LIVY 4 x 0.14 mm² connecting cable is 4 m long.<br />

VSUE<br />

GH-<br />

V9210018V0022<br />

Data logging unit, MDRC 1 )<br />

The data logging unit BDB/S 1.1 is a KNX device for serial<br />

installation with 2 MW module widths. The device is used<br />

for the recording of switch play and operating hours, for<br />

example, of 35 switch actuator channels. In addition, limits<br />

can be set. If the limits are exceeded, alarm messages are<br />

transmitted on the bus. The BDB/S 1.1 is supplied by the<br />

ABB i-bus ® KNX and requires no additional power supply.<br />

The bus is connected through a bus connecting terminal<br />

located on the front of the unit.<br />

Dimensions: (L x W x D): 90 mm x 36 mm x 64 mm<br />

Installation depth: 68 mm<br />

module width: 2 MW<br />

BDB/S 1.1 2CDG110067R0011<br />

Meter interface unit, MDRC 1 )<br />

The meter unit module records consumption and measured<br />

values of electrical power consumption counters via<br />

ABB i-bus ® . The device has an infrared interface by means<br />

of which ABB can read power consumption counters of<br />

the types DELTAplus, DELTAsingle, and ODIN respectively.<br />

The read information and data, for example, can<br />

be used for cost centre accounting, power optimisation,<br />

visualisation, or installation monitoring.<br />

Dimensions: (L x W x D): 90 mm x 72 mm x 64 mm<br />

Installation depth: 68 mm<br />

module width: 2 MW<br />

ZS/S 1.1 2CDG110083R0011<br />

Power module * )<br />

3-channel<br />

The SM/S 3.16.30 current module permits the measurement<br />

of load and/or fault currents.<br />

For this purpose, it has 3 fl oating, independent power or<br />

measuring circuits.<br />

The current load and fault current value can be transmitted<br />

as a 1-byte telegram via ABB i-bus ® KN X.<br />

In addition, 2-bit switch programs can be transmitted via<br />

ABB i-bus ® KNX when parameterised threshold values are<br />

exceeded or undershot.<br />

Inputs: 3<br />

Protection class (Device): IP 20<br />

module width: 4 MW<br />

SM/S 3.16.30 GHQ6310034R0111<br />

Product Article-No. Order-No. Pack/Qty<br />

1) 1 MW 18 mm.<br />

Fault monitoring unit, MDRC<br />

The fault monitoring unit SMB/S 1.1 is used to detect up<br />

to 100 fault messages via ABB i-bus ® KNX.<br />

The fault messages are prepared in the module and can<br />

be passed on to a display.<br />

In addition, an optical and acoustic collective message is<br />

available on the bus.<br />

Messages can be acknowledged and data losses can be<br />

indicated.<br />

The SMB/S 1.1 supports the following message types defi<br />

ned in DIN 19 235: indication with continuous light, new<br />

value indication with light that fl ashes once, new value<br />

indication with one-time acknowledgement, and motor<br />

indication. Current values can be scanned in a centralised<br />

manner.<br />

Connections:<br />

KNX-line: Bus terminal<br />

Protection class (Device): IP 20<br />

module width: 2 MW<br />

SMB/S 1.1 GHQ6310085R0111<br />

Monitoring unit, MDRC<br />

The KNX monitoring unit EUB/S 1.1 is used to monitor up<br />

to 100 bus stations in ABB i-bus ® KNX installations.<br />

Bus stations are monitored for existence and minimum<br />

functionality.<br />

For this purpose, four types of monitoring are available.<br />

Individual bus su<strong>bs</strong>cribers can be collected in up to 5<br />

groups for monitoring purposes.<br />

Bus connection: via bus connecting terminal; mounting:<br />

on support rail 35 mm, DIN EN 60715; width: 2 modules<br />

with 18 mm each; degree of protection: IP20 DIN EN<br />

60529.<br />

Connections:<br />

KNX-line: Bus terminal<br />

Protection class (Device): IP 20<br />

module width: 2 MW<br />

EUB/S 1.1 2CDG110066R0011<br />

Universal I/O concentrator 1 )<br />

The universal I/O concentrator is used to connect<br />

push-switches or signal lamps to ABB i-bus ® , e.g in an<br />

operating/display panel. It has 32 channels, which are<br />

freely parameterisable as inputs or outputs using ETS. The<br />

device needs an external auxiliary voltage of 12 V DC or<br />

24 V DC, e.g. NT/S 24,800.<br />

Dimensions: (L x W x D): 90 mm x 72 mm x 64 mm<br />

Installation depth: 68 mm<br />

module width: 4 MW<br />

UK/S 32.2 2CDG110071R0011<br />