Active System with Short Circuit<br />

Installation details<br />

Figure 17 shows an active system incorporating a short circuit. Hot water is only directed to<br />

the tank if the water temperature from the collector is above a set temperature. If not, the<br />

collector water is circulated back through the manifold via a 3-way valve. This type of installation<br />

is recommended where a long distance is between the collector and the hot water storage<br />

tank.<br />

Multiple Tank Installation - Series<br />

F igure 17<br />

For large installations two or more tank s may be connected to the solar sy stem in series (preheat).<br />

Using 3-way valves hot water from the collector passes through Tank 1 first, if the return<br />

temperature is above a set temperature it passes via a 3-way valve to Tank 2 (first pre-heat<br />

tank). Otherwise, it is circulated back to the collector. If water leaving Tank 2 is above a set<br />

temperature it is passed to Tank 3 (second preheat tank). This process may be repeated for a<br />

number of preheat tanks (Figure 18).<br />

F igure 18<br />

16