LD 15: Customer Data Block<br />

Prompt Response Comment<br />

REF3 xxxx DN for <strong>Reference</strong> trunk 3<br />

TST3 xxxx DN for Test trunk 3<br />

Alphabetical list of prompts<br />

Prompt Response Comment Pack/Rel<br />

ABDN (NO) YES Activation of the Attendant Blocking of DN abdn-20<br />

Prompted with Semi-Automatic Camp-On<br />

(SACP) package 181.<br />

AC2 Access Code 2 pri-15<br />

NPA E.164 National<br />

NXX E.164 Subscriber<br />

INTL International<br />

SPN Special Number<br />

LOC Location Code<br />

For DPNSS1, only SPN and LOC values<br />

apply.<br />

Enter call types that use Access Code 2 (AC2)<br />

Multiple responses are permitted. If a<br />

numbering plan is not entered here, it is<br />

automatically defaulted to Access Code1<br />

(AC1).<br />

This prompt applies to both ISDN and non-<br />

ISDN calls if you have Network Message<br />

Services (NMS) package175.<br />

ACCD (OVF OVF OVF ATN) basic-1<br />

Access Denied<br />

ACNS Attendant Clearing during Night Service mpo-20<br />

(NO) No automatic treatment<br />

EXT External calls only<br />

ALL All calls<br />