LD 17: Configuration Record 1<br />

Prompt Response Comment Pack/Rel<br />

DES is used to identify the link and can be<br />

up to 16 alphanumeric characters: 0-9, and<br />

upper case (A-Z) including spaces<br />

separating inputs. Characters * and # are not<br />

allowed.<br />

Spaces are removed by the system. For<br />

example: CAB 5 PORT 2 becomes<br />

CAB5PORT2. Use the underscore character<br />

(_) instead, for example: CAB_5_PORT_2.<br />

DES can be left blank or changed as<br />

required. If DES is already defined for a link,<br />

the system outputs the current name and reprompts<br />

DES.<br />

Precede the existing DES with X to remove.<br />

Example: XCAB_5_PORT_2.<br />

DIDD (0)-15 DID Delete<br />

Number of leading digits to delete when<br />

receiving digits from DID trunk.<br />

DLAC (NO) YES Change Call Log Option, where:<br />

YES - Log all calls<br />

NO - Log unanswered calls<br />

DLOP lll dd ff Digital Trunk Interface Loop or Loops.<br />

Where:<br />

lll = 0-159<br />

lll = 1-9 11-19 21-29 31-39 41-49 Small<br />

System<br />

isdn-16<br />

basic-7.00<br />

dti-5<br />

lse-25<br />

lll = 0-255 systems with Fibre Network Fabric fnf-25<br />

lll = 11-14, 21-24, 31-34, 41-44 for CS 1000S basic-1<br />

lll is 0-255 for CS 1000E system and no dd<br />

or ff<br />

dd = maximum number of simultaneous<br />

voice or data calls 0-(24)<br />

ff = frame format D2, D3, D4, or ESF<br />

The default for frame format ff is ESF if<br />

prompt MODE is set to PRI; D3 if MODE is<br />

set to DTI or LINK. Loop must be removed<br />

before a change to ff can be made.<br />

X to delete the loop.<br />

L1 L2 Ln Digital Trunk Interface Loop or Loops<br />

Loop numbers of the DTI Loops associated<br />

with this VAS. Loops must have previously<br />

518 Nortel Communication Server 1000 April 2011