Communicating with the system<br />

Low memory and disk warnings<br />

If the amount of memory or disk space is low, the following messages are output on the<br />

systems.<br />

WARNING: LOW MEMORY WARNING: LOW DISK WARNING: LOW MEMORY/DISK<br />

Note:<br />

The LOW DISK messages are not displayed after sysload and until a data dump is<br />

performed.<br />

Warning:<br />

When the LOW MEMORY, LOW DISK, or LOW MEMORY/DISK messages appear, avoid<br />

performing further administration changes which require more memory and disk space.<br />

These changes can be lost during the next data dump.<br />

When low memory or disk problems occur, a review of system memory is recommended.<br />

Memory can be reclaimed by removing unused features. For example, the system may have<br />

speed call lists which are no longer used and can be removed.<br />

Depending on the data storage type required (such as protected/ unprotected), it can be<br />

necessary to perform an initialize or sysload to access the reclaimed data store space.<br />

A disk record stores approximately 500 words of protected data store. A single 3.5 inch high<br />

density floppy disk can hold a maximum of 1425 records.<br />

When the software detects that more than one floppy disk is required, the data is compressed<br />

during the backup, thereby reducing the number of disks required.<br />

System Lookup messages<br />

On systems equipped with System Errors and Events Lookup package 245, it is possible to<br />

display system messages on screen. Specific system messages may then be viewed on<br />

screen if the user enters ERR followed by the desired system error code and . The<br />

following example shows the data entries necessary to view error message SCH946:<br />

• Login to switch<br />

• PASS (Enter only your password)<br />

• ERR SCH946(The user must type "ERR SCH946" and press return)<br />

The screen displays the error message corresponding to SCH946. In this case, that message<br />

is:<br />

Invalid User Type<br />