Chapter 4 Operation<br />

Table 4-4. Warning Messages<br />

Warning Message Meaning Corrective Action<br />

Absorbance is too negative!<br />

Try rezeroing the analyzer<br />

and make sure zero gas is<br />

not contaminated.<br />

Analyzer factory<br />

configuration is invalid!<br />

Analyzer memory is<br />

invalid.<br />

Battery pack capacity<br />

getting low!<br />

Battery pack charge is low!<br />

Not enough power to run<br />

analyzer.<br />

Battery pack data is invalid!<br />

Battery pack needs full<br />

charge, then discharge to<br />

update capacity data.<br />

This message is generated if the measured<br />

absorbance falls below a negative<br />

absorbance threshold value set in the<br />

application. Try rezeroing the analyzer to<br />

correct the problem<br />

4-14<br />

Rezero the analyzer. If<br />

problem persists,<br />

replace the zero gas<br />

filter.<br />

This message is displayed only during the<br />

power-on self-test if the factory<br />

Return analyzer to TEI<br />

configuration is not valid. The analyzer can for service.<br />

operate with a minimum feature set.<br />

The data in the analyzer's battery-backed up<br />

RAM is invalid. All settings are reset to<br />

factory default values if this message is<br />

displayed. If the analyzer power is cycled<br />

again and this message persists, the backup<br />

battery may be dead.<br />

This message indicate the battery pack has<br />

reached the end of its lifetime.<br />

This message indicates the battery is too<br />

low to run the system. The system is shut<br />

down shortly after this message is<br />

displayed.<br />

This message indicates the battery pack has<br />

not been initialized.<br />

This message is displayed if the battery has<br />

not been fully discharge before it has been<br />

recharged many times.<br />

Contact TEI for<br />

assistance.<br />

Replace the battery<br />

pack with a new one.<br />

To continue operation,<br />

replace the battery with<br />

a fresh battery or<br />

connect the analyzer to<br />

a charger.<br />

Contact TEI customer<br />

service for a new<br />

battery pack.<br />

Perform battery<br />

indicator calibration<br />

(see page 3-7).