Application Instructions<br />

Application Instructions<br />

For product description refer to product data sheet<br />

Issued: March 2010 Page 1 of 4<br />

HEMPEL’S VINYL ESTER GF 35910<br />

HARDENER 99410<br />

Scope: These Application Instructions cover surface preparation, application equipment, and<br />

application details for HEMPEL’S VINYL ESTER GF 35910.<br />

Surface preparation: New steel: Remove oil and grease, etc. with suitable detergent. Remove salt and other<br />

contaminants by (high pressure) fresh water cleaning. Abrasive blasting to Sa 2½.<br />

Minimum surface profile corresponding to Rugotest No. 3, BN11, Keane-Tator<br />

Comparator, 5.5 G/S, or ISO Comparator Coarse (G). After blasting, clean the surface<br />

carefully from abrasives and dust.<br />

On pit-corroded surfaces, excessive amounts of salt residues may call for dry abrasive<br />

blasting, high pressure fresh water hosing, drying, and finally, dry abrasive blasting<br />

again as described above.<br />

Galvanized, Zinc primed steel etc.: Metallic zinc inhibits the curing process - the<br />

product is not compatible with galvanized steel or other zinc coated substrates. Steel<br />

primed with zinc dust containing pre-fabrication primers must be re-blasted to min. Sa<br />

2½-3 to remove all traces of zinc.<br />

Application equipment: HEMPEL’S VINYL ESTER GF 35910, being a high-viscosity material, requires special<br />

measures to be taken at application.<br />

Standard airless heavy-duty spray equipment:<br />

Pump ratio: min 60:1 (See Note below)<br />

Pump output: min. 12 litres/minute (theoretical)<br />

Input pressure: min. 6 bar/90 psi<br />

Spray hoses: max. 50 metres/150 feet, 3/8" internal diameter, nylon lined<br />

max. 3 metres/10 feet, 1/4" internal diameter<br />

Regular surfaces:<br />

Nozzle size: .030" through .060"<br />

reversible tip<br />

Fan angle: 40-60°<br />

Filter: Surge tank filter and tip filter should be removed.<br />

Note: Avoid the use of a suction hose. Use an interchangeable pipe, which makes it<br />

possible to remove cured paint.<br />

The pump should preferably be fitted with leather seals although Teflon (PTFE) seals are<br />

acceptable for small jobs.<br />

Pump ratio 60:1 is recommended, however, if only 45:1 is available, it is recommended<br />

to shorten the hoses to 15 metres/50 feet hose (Min. ½” internal diameter)Before<br />

application starts, the filter should be removed and hoses should be washed with<br />

styrene.<br />

Thinning: Do not thin. Alternatively max. 5% styrene may be added, but this must be done with<br />

care as the anti-sagging properties are drastically reduced and chemical resistance may<br />

be affected.<br />

Airless spray data are indicative and subject to adjustment.<br />

HEMPEL<br />