Annex B - Parameter Summary <strong>F0</strong>MAIN MENURUN ParameterPage 37-40r.0 : prom no. r.14 : input terminal statusr.1 : inverter status r.15 : output terminal statusr.2 : actual value display r.18 : bus address displayr.3 : set value display r.19 : reference setting 1)r.4 : output voltage r.201) 2): rotation settingr.5 : DC voltage r.21 : password inputr.6 : DC circuit peak voltage r.22 : select parameter groupr.7 : current inverter utilization r.23 : select parameter setr.8 : peak load r.29 : current frequencyMAIN MENUo.0o.1o.2o.6o.8o.13o.14o.15o.16o.17Operation ParameterPage 41-44: boost 1): minimum reference A 1): maximum reference A 1): acceleration time A 1): deceleration time A 1)1) 2): input source: Delta - Boost 1): Delta - Boost time 1): s-curve acceleration time A 1): s-curve deceleration time A 1) P.0P.1P.2P.3P.4P.6P.7P.11P.12P.13Protection ParameterPage 45-50: stall prevention level 1): acc / dec time during stall prevention 1)1) 2): stall torque characteristic: LAD stop load level 1): U/f - function 1): speed search condition 1): automatic retry UP 1)1) 2): energy - saving mode: energy - saving level 1): LAD stop condition 1)H.0H.1H.3H.4H.5H.7H.8H.9H.10H.11Input / Output HandlerPage 51-531) 2): presetting mode reference value1) 2): logic of analog inputs1) 2): output logic1) 2): Out 1 - function1) 2): Out 2 - function: input logic 2): In -function parameter set 2)1) 2): analog output function: analog output offset y 1): analog output gain 1) L.0L.1L.2L.3L.6L.7L.8L.16L.17Level ParameterPage 54-56: actual value level 1 1): actual value level 2 1): load level 1 1): load level 2 1): DC dynamic braking level 1): DC dynamic braking voltage 1): DC dynamic braking time 1): timer value 1): timer adding value 1)P.15 : load-dependent set shifting level 1)P.14 : LD stop DC voltage level 1)SUBMENUDrive ParameterPage 57-61d.0 : rated frequency 1)d.1 : f-mode 1)d.2 : lower modulation limit 1)d.4 : rated motor power 1)d.18 : slip compensation / frequency gain 1)d.19 : slip compensation / auto torque gain 1)d.20 : slip compensation / min. frequency 1)d.21 : slip compensation / max. frequency 1)d.22 : slip compensation / no-load losses 1)d.23 : slip comp./load-no-load differ.displayd.24 : number of pole pairs 1)Free-programmable Parameter SetsPage 71-74F.0 : key parameter set no.F.3 : based on para setF.4 : global enterF.5 : clear top parameter setF.6 : bus parameter set no.F.7 : save last bus parameterSUBMENU✃Parameters for Standard Applications!1) Parameters that can be changed in parametersets 1 to 6!2) Parameter value is stored only after pressing "EN-TER" twice!Customer ParameterPage 62-70C.0 : limit of maximum reference A 1)C.21) 2): rotation lockC.4 : condition displayC.5 : noise fi lter / digital inputsC.6 : DC level auto set 1)C.71) 2): DC-braking modeC.8 : carrier frequency 1)C.9 : parameter group lockC.101) 2): output voltage stabilizationC.12 : baud rateC.13 : inverter addressC.14 : zero clamp speed 1)C.151) 2): select mode of modulationC.21 : watchdog timeC.25 : control word activationC.27 : application selectionInformation ParameterPage 75-76I.0 : inverter typeI.1 : rated inverter current displayI.2 : output frequency limit displayI.3 : error counter OPI.4 : error counter UPI.5 : error counter OCI.6 : error counter OHI.7 : error counter OLI.8 : error counter set selectionI.9 : error counter watchdogPr.5Pr.6Pr.7Pr.8Pr.9Pr.10Pr.11Pr.16Pr.18Pr.25Pr.27Pr.37Profil ParameterPage 77-79: malfunction code: control word: status word: nominal speed value: actual speed value: speed-min-amount: speed-max-amount: acceleration-delta speed: acceleration-delta time: deceleration-delta speed: deceleration-delta time: speed reference value

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!