Effect<br />
Cause<br />
GB<br />
Solution<br />
4<br />
La pompa di calore non funziona.<br />
There is no communication with the<br />
external unit and on the control panel<br />
display of the external unit the symbol<br />
appears and is accompanied by the prompt<br />
R.C.1.<br />
Open the inspection panel of the external<br />
unit and press the AUTO ADD button<br />
(Automatic address button) positioned on<br />
the electronic board (fig. 25).<br />
In version 15 or 18 three-phase, alarm<br />
P05 appears on the control panel of the<br />
external unit.<br />
Invert two of the three-phase power<br />
supply phases<br />
Line voltage is too low.<br />
Contact an electrician or your installer.<br />
The operation pushbutton is in the off<br />
position.<br />
Press the pushbutton again.<br />
The wire remote control or the heat pump<br />
does not work correctly (the inspection<br />
symbol as well as the letters E, F, H, L, P<br />
and some numbers appear on the liquid<br />
crystal display of the remote control).<br />
Contact the installer.<br />
Presence of an obstacle in front of the<br />
external unit exchanger.<br />
Remove the obstacle.<br />
The compressor switches on but stops<br />
immediately after.<br />
Problem with the circulation of water.<br />
Clean and/or check the heating hydraulic<br />
circuit.<br />
Unsatisfactory heating.<br />
The programmed outflow water<br />
temperature is adjusted to a value that is<br />
too low (heating mode) or too high<br />
(cooling mode) on the control box.<br />
Doors and/or windows open.<br />
The thermostat is adjusted to a<br />
temperature that is too high for cooling (or<br />
too low for heating).<br />
Close them in order to prevent air from<br />
entering.<br />
Adjust the temperature to a higher or lower<br />
value.<br />
Defrosting of the system does not work.<br />
Contact the installer.<br />
If during operation of the unit there is an interruption in the current, when the power is reconnected the unit will restart<br />