TECHNICAL CHARACTERISTICS 4.3<br />

4<br />

PERFORMANCE<br />

Sherpa 8M Sherpa12M Sherpa15M Sherpa15T Sherpa18T<br />

heating capacity (*) k W 8,2 11,2 14,6 14,6 16,9<br />

power input<br />

(included water pump) k W 1,88 2,62 3,35 3,35 4,17<br />

COP 4,36 4,27 4,36 4,36 4,05<br />

heating capacity (**) k W 4,7 6,8 8,7 8,7 10,8<br />

power input<br />

(included water pump) k W 1,91 2,67 3,4 3,4 4,22<br />

COP 2,46 2,55 2,56 2,56 2,56<br />

cooling capacity (***) k W 6,27 8,84 11,2 11,2 13,9<br />

power input<br />

(included water pump) k W 2,13 2,97 3,78 3,78 4,7<br />

EER 2,94 2,98 2,96 2,96 2,96<br />

cooling capacity (****) k W 8,72 12,29 15,57 15,57 19,32<br />

power input<br />

(included water pump) k W 2,24 3,13 3,98 3,98 4,95<br />

EER 3,89 3,93 3,91 3,91 3,90<br />

indoor sound level<br />

sound power level dB(A) 40,9 41,9 41,9 41,9 41,9<br />

sound pressure level dB (A) 30 31 31 31 31<br />

outdoor sound level<br />

sound power level dB(A) 61 62 62 62 63<br />

sound pressure level dB (A) 48 49 49 49 50<br />

hydraulic data<br />

Nominal water flow in heating<br />

(30/35°C) l/h 1,410 1,926 2,511 2,511 2,907<br />

available pressure head kPa 58 31 31 31 51<br />

Hydraulic connections dimension " GAS 1 1 1 1 1 ¼<br />

expansion vessel volume l 6 6 6 6 6<br />

Minimum system water content l 40 50 65 65 75<br />

minimum inlet/outlet water<br />

temperature difference °C 4 4 4 4 4<br />

maximum inlet/outlet water<br />

temperature difference °C 7 7 7 7 7<br />

minimum hydraulic<br />

system pressure bar 0,5 0,5 0,5 0,5 0,5<br />

maximum hydraulic<br />

system pressure bar 2,5 2,5 2,5 2,5 2,5<br />

Refrigerant fittings<br />

liquid line diameter<br />

refrigerant valve " SAE 3/8 3/8 3/8 3/8 3/8<br />

suction line diameter<br />

refrigernat valve " SAE 5/8 5/8 5/8 5/8 5/8<br />

REFRIGERANT R410 LOAD kg 1,9 2,8 3,6 3,6 3,6<br />

Electrical supply<br />

Voltage V/50Hz 230 230 230 400-3N 400-3N<br />

Unit protection IPX2 IPX2 IPX2 IPX2 IPX2<br />

indoor unit dimensions<br />

width mm 505 505 505 505 505<br />

height mm 900 900 900 900 900<br />

depth mm 300 300 300 300 300<br />

weight kg 43 43 45 45 48<br />

outdoor unit dimension<br />

width mm 940 940 940 940 940<br />

height mm 780 780 1230 1230 1230<br />

depth mm 340 340 340 340 340<br />

weight kg 67 73 109 109 109<br />

Performances detected according to standard EN14511<br />