4 GB<br />

4.2.2 Meaning of the warning lights on the electronic board of the external unit<br />

ME = external unit switched on • switched off<br />

°<br />

D<br />

<br />

flashing (0.25/0.75) - the warning light remains switched on for 0.25 seconds, then remains switched off for 0.75 seconds.<br />

In the absence of other indications the warning light flashes (0.5/0.5)<br />

Meaning<br />

LED 1<br />

LED 2<br />

Notes<br />

When powered :<br />

1. absence of communication with the MI of<br />

the system<br />

2. communication established with one or<br />

more MI of the system<br />

3. normal communication OK (power and<br />

quantity checked)<br />

°<br />

•<br />

•<br />

°<br />

°<br />

•<br />

When it is not possible to move to<br />

point 3, repeat the operations<br />

described in points 1 and 2.<br />

At point 3, the warning lights<br />

switch-off.<br />

When in normal operation:<br />

Error EEPROM (F31)<br />

Pre-trip (insufficient load)<br />

Pre-trip (P20)<br />

Pre-trip (other)<br />

°<br />

(0.25/0.75)<br />

(0.75/0.25)<br />

<br />

<br />

•<br />

•<br />

•<br />

Display upon initial automatic<br />

addressing and communication<br />

set-up.<br />

P03<br />

Alarms<br />

Missing load indicator<br />

Refrigerant recovery mode<br />

Alternate flashing during alarm<br />

LED 1 flashes M times, then LED 2 flashes N<br />

times.<br />

The cycle then repeats.<br />

M = 2 : Alarm P 3 : Alarm H 4 : Alarm E<br />

M = 5 : Alarm F 6 : Alarm L<br />

N := alarm number<br />

(see the following table with examples)<br />

<br />

<br />

•<br />

•<br />

Automatic addressing<br />

Automatic addressing in course<br />

<br />

<br />

Alternating flashing<br />

Automatic addressing alarm (E15)<br />

(0.25/0.75)<br />

(0.25/0.75)<br />

Simultaneous flashing<br />

Automatic addressing alarm (E20)<br />

Other automatic addressing alarms<br />

(0.75/0.25)<br />

<br />

(0.75/0.25)<br />

<br />

Simultaneous flashing<br />

Simultaneous flashing<br />