Alarms<br />
displayed<br />
Meaning<br />
Condition for the<br />
alarm signalling<br />
Condition for alarm<br />
interruption<br />
Check and<br />
connections<br />
P26<br />
Protection circuit<br />
Inverter connected or GTR<br />
in short-circuit (short<br />
period of 0.8 sec or less)<br />
in the Inverter check<br />
Stop of the Inverter after the<br />
defect has been detected<br />
Alarm is displayed after 4<br />
consecutive stops<br />
Interruption when restarted<br />
1. Immediate stop or<br />
restart<br />
2. Check the Inverter<br />
board: cabling defect<br />
P29<br />
Defect in the power supply<br />
The Inverter blocks after the<br />
intervention of the alarm.<br />
The alarm is displayed after<br />
4 consecutive stops of the<br />
Inverter<br />
Interruption when restarted<br />
1. Immediate stop after<br />
restart<br />
2. Check the Inverter<br />
board: cabling defect<br />
Compressor defect<br />
Compressor inverter<br />
defect<br />
MDC defect<br />
Stop of the inverter after<br />
intervention of the alarm<br />
Interruption when restarted<br />
1. Thermodynamic defect<br />
Operating in overload<br />
2. Tightening defect<br />
between the HIC board<br />
and cooling radiator<br />
3. Cooling defect of the<br />
radiant plate<br />
4. Check external board<br />
cabling<br />
The compressor does not<br />
work (the overcurrent<br />
protection was activated<br />
some time after the re-start<br />
of the compressor)<br />
Stop of the inverter after<br />
intervention of the alarm<br />
Interruption when restarted<br />
1. Compressor defect<br />
(block, etc.): replace<br />
the compressor<br />
2. Power supply defect to<br />
the compressor<br />
(missing phase)<br />
Compressor malfunction.<br />
The frequency decreases<br />
shortly after start up then it<br />
stops<br />
Stop of the inverter after<br />
intervention of the alarm<br />
Interruption when restarted<br />
1. Check the power<br />
supply voltage 200V +/<br />
- 20V<br />
2. Thermodynamic circuit<br />
in overload<br />
3. Check the CA control<br />
circuit<br />
Defect in the state of the<br />
inverter board check<br />
Stop of the inverter after<br />
intervention of the alarm<br />
Interruption when restarted<br />
The controller of the state is<br />
activated even when the 3P<br />
connector is disconnected<br />
- replace the Inverter<br />
control board<br />
F04<br />
Reflow probe (TD)<br />
disconnected, interrupted<br />
or in short circuit<br />
Probe defect detected (90°C<br />
or above, 15 min after the<br />
stop of the compressor).<br />
(conductor interrupted)<br />
Interruption when restarted<br />
1. Check the reflow<br />
probe (TD)<br />
2. Connect the external<br />
electronic board<br />
F06<br />
Exchanger probe (C1)<br />
disconnected, interrupted<br />
or in short circuit<br />
Interruption or short circuit<br />
Interruption when restarted<br />
1. Check the external<br />
exchanger probe (C1)<br />
2. Connect the external<br />
electronic board<br />
F07<br />
Exchanger probe (C2)<br />
disconnected, interrupted<br />
or in short circuit<br />
Interruption or short circuit<br />
Interruption when restarted<br />
1. Check the external<br />
exchanger probe (C2)<br />
2. Connect the external<br />
electronic board<br />
F08<br />
External temperature<br />
probe (TO) disconnected,<br />
interrupted or in short<br />
circuit<br />
Interruption or short circuit<br />
Interruption when restarted<br />
1. Check the external<br />
temperature probe<br />
(TO)<br />
2. Connect the external<br />
electronic board<br />
F12<br />
Aspiration probe (TS)<br />
disconnected or in short<br />
circuit<br />
Interruption or short circuit<br />
Interruption when restarted<br />
1. Check the aspiration<br />
probe (TS)<br />
2. Connect the external<br />
electronic board<br />
F31<br />
EEPROM defect<br />
Lack of reading or writing<br />
Interruption of the alarm for<br />
interruption to the power<br />
supply + restoration of the<br />
power supply<br />
1. Check EEPROM<br />
(IC0901)<br />
2. Check the ME<br />
electronic board<br />
56