12.01.2021 Views

Motors-D81.1-complete-English-06-2020

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

© Siemens <strong>2020</strong><br />

SIMOTICS GP and SIMOTICS SD standard motors<br />

IE1 Standard Efficiency<br />

Please note<br />

minimum legal<br />

efficiencies<br />

in the European<br />

Economic Area!<br />

Cast-iron series SIMOTICS SD 1LE1502 Basic Line with increased power – self-ventilated or forced-air cooled<br />

2<br />

■ Selection and ordering data<br />

P rated,<br />

50 Hz/<br />

P50<br />

P rated,<br />

60 Hz/<br />

P60 1)<br />

Frame<br />

size<br />

Operating values at rated power<br />

n rated,<br />

50 Hz<br />

T rated, rated,<br />

50 Hz 50 Hz,<br />

4/4<br />

rated,<br />

50 Hz,<br />

3/4<br />

rated,<br />

50 Hz,<br />

2/4<br />

cos rated,<br />

50 Hz,<br />

4/4<br />

I rated,<br />

50 Hz,<br />

400 V<br />

T LR / I LR / T B / L pfA,<br />

T rated, I rated, T rated, 50 Hz<br />

50 Hz 50 Hz 50 Hz<br />

L WA,<br />

50 Hz<br />

Cast-iron series<br />

1LE1502 – Basic Line<br />

Article No.<br />

kW kW FS rpm Nm % % % A dB(A) dB(A) kg kgm 2<br />

• Cooling: Self-ventilated (IC411) or with order code F90 forced-air cooled without external fan and fan cover (IC418)<br />

• Efficiency according to IEC 60034-30-1: IE1 Standard Efficiency, service factor (SF) 1.1<br />

• Insulation: Thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)<br />

2-pole: 3000 rpm at 50 Hz, 3600 rpm at 60 Hz 1)<br />

4 4.6 100 L 2850 13 83.1 83.9 83 0.85 8.2 4.5 7 4.1 67 79 1LE1502-1AA6■-■■■■ 33 0.0044<br />

5.5 6.3 112 M 2935 18 84.7 84.7 82.7 0.86 10.9 2.9 7.5 3.8 69 81 1LE1502-1BA6■-■■■■ 40 0.0085<br />

11 12.6 132 M 2920 36 87.6 88.3 87.8 0.9 20 2.8 7.5 3.7 68 80 1LE1502-1CA6■-■■■■ 76 0.022<br />

22 24.5 160 L 2935 72 89.9 90.2 89.5 0.9 39 2.6 7.5 3.4 70 82 1LE1502-1DA6■-■■■■ 125 0.049<br />

30 33.5 180 L 2940 97 90.7 91.5 91.5 0.89 54 2.4 8.1 3.5 72 85 1LE1502-1EA6■-■■■■ 180 0.094<br />

45 51 200 L 2955 145 91.7 92.3 92.4 0.85 83 2.5 8.1 3.6 71 85 1LE1502-2AA6■-■■■■ 245 0.176<br />

55 62 225 M 2960 177 92.1 92.4 92 0.88 98 2.5 7.3 3.2 76 89 1LE1502-2BA6■-■■■■ 330 0.27<br />

75 84 250 M 2970 241 92.7 92.8 92.1 0.87 134 2.4 7.3 3.1 76 89 1LE1502-2CA6■-■■■■ 420 0.48<br />

110 123 280 M 2975 353 93.3 93.5 93.1 0.9 189 2.4 7.3 3.1 77 90 1LE1502-2DA6■-■■■■ 620 1<br />

4-pole: 1500 rpm at 50 Hz, 1800 rpm at 60 Hz 1)<br />

4 4.6 100 L 1435 27 83.1 83.8 82.3 0.81 8.6 2.9 5.8 3.1 60 72 1LE1502-1AB6■-■■■■ 36 0.01<br />

5.5 6.3 112 M 1420 37 84.7 85.9 85.3 0.81 11.6 3 5.8 3.1 58 70 1LE1502-1BB6■-■■■■ 43 0.012<br />

11 12.6 132 M 1450 72 87.6 88.2 87.6 0.84 21.5 2.5 7.2 3 64 76 1LE1502-1CB6■-■■■■ 76 0.033<br />

18.5 21.3 160 L 1460 121 89.3 89.8 89.2 0.85 35 2.7 7.2 3.2 65 77 1LE1502-1DB6■-■■■■ 125 0.<strong>06</strong>8<br />

30 34.5 180 L 1465 196 90.7 91.7 91.9 0.79 60 2.6 7.2 3.4 64 77 1LE1502-1EB6■-■■■■ 185 0.159<br />

37 42.5 200 L 1470 240 91.2 92 92.1 0.82 71 2.4 6.8 2.9 64 78 1LE1502-2AB6■-■■■■ 240 0.246<br />

55 63 225 M 1475 356 92.1 92.8 92.6 0.86 100 2.5 6.7 2.6 70 83 1LE1502-2BB6■-■■■■ 320 0.49<br />

75 86 250 M 1482 483 92.7 93.1 92.6 0.84 139 2.5 7.4 3 73 87 1LE1502-2CB6■-■■■■ 440 0.86<br />

110 127 280 M 1486 707 93.3 93.5 93 0.85 200 2.6 8 3.3 75 89 1LE1502-2DB6■-■■■■ 670 1.7<br />

Voltages 2) Version Order code<br />

50 Hz 230 V/400 VY 60 Hz 1) 460 VY Standard 2 2 –<br />

50 Hz 400 V/690 VY 60 Hz 1) 460 V Standard 3 4 –<br />

50 Hz 500 VY Without additional charge 2 7 –<br />

50 Hz 500 V Without additional charge 4 0 –<br />

For other voltages 1) and more information, see from page 2/96 9 0 . . .<br />

Types of construction Version Order code<br />

Without flange IM B3 3) Standard A –<br />

With flange IM B5 3) With additional charge F –<br />

With flange IM B14 3) With additional charge K –<br />

For other types of construction and more information, see from page 2/103 ■ . . .<br />

Motor protection Version Order code<br />

Without Standard A –<br />

PTC thermistor with 3 temperature sensors With additional charge B –<br />

For other motor protection and more information, see from page 2/113 ■ . . .<br />

Terminal box position<br />

Version<br />

Terminal box at top Standard 4<br />

For other terminal box positions and more information, see from page 2/116<br />

■<br />

Special versions<br />

Order code(s)<br />

Forced-air cooled motors w/o ext. fan/fan cover (IC418) 1LE1502- . . . . ■-■■■■ -Z F90 +. . .+. . .+. . .<br />

For options, see from page 2/125 1LE1502- . . . . ■-■■■■ -Z . . .+. . .+. . .+. . .<br />

m IM B3<br />

J<br />

1)<br />

2)<br />

Operating values at rated power for 60 Hz are stored in the<br />

Drive Technology Configurator (DT Configurator; see Appendix,<br />

"Tools and engineering").<br />

Parallel supply lines are required in the case of connection to 240 V.<br />

For frame size 315 with connection to 240 V, due to the high current, a<br />

drilled, removable entry plate (order code R52) or a larger terminal box<br />

(order code R50) can be used. Order codes R52 and R50 alter the motor<br />

dimensions.<br />

3)<br />

Types derived from IM B3 (IM B6/7/8, IM V6 and IM V5), from IM B5 (IM V3<br />

and IM V1) and from IM B14 (IM V19 and IM V18) are possible, provided<br />

that no requirement exists for stamping of the type on the rating plate. The<br />

basic type IM B3, IM B5, or IM B14 is stamped as standard on the rating<br />

plate. If mounted in a different position, the position must be specified to<br />

ensure that the condensation drainage holes are positioned correctly.<br />

2/56 Siemens D 81.1 · <strong>06</strong>/<strong>2020</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!