© Siemens <strong>2020</strong><br />

SIMOTICS XP 1MB1, 1MB5 explosion-protected motors<br />

Article No. supplements and special versions · Terminal box position<br />

Cast-iron series 1MB1553, 1MB5553<br />

■ Selection and ordering data<br />

Terminal box position Article No. supplement Frame size Motor version<br />

6<br />

4<br />

7<br />

5<br />

1MB.553 - . . . . . - . . . ■<br />

Terminal<br />

box position<br />

code<br />

16th position<br />

of the<br />

Article No.<br />

Additional 71 80 90 100 112 132 160 180 200 225 250 280 315 355<br />

identification<br />

1MB1553 IEC Ex db, Ex db eb<br />

code with<br />

order code<br />

1MB5553<br />

(Zone 1)<br />

and plain text,<br />

if required<br />

Order code<br />

Terminal box position<br />

Terminal box top 1) 4 – <br />

Terminal box right-hand side 1) 5 – – – – – – ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Terminal box left-hand side 1) 6 – – – – – – ✓ ✓ ✓ ✓ ✓ ✓ ✓ – –<br />

Terminal box bottom 2) 7 – – – – ✓ ✓ ✓ ✓ – – – – – – –<br />

Standard version<br />

✓ With additional charge<br />

– Not possible<br />

Standard version:<br />

Cable entry from right, as seen looking onto the shaft, with terminal box position left, entry from below, on frame size 355 and with<br />

terminal box on the right-hand side, cable entry is from the NDE.<br />

IE3<br />

5<br />

1)<br />

2)<br />

For types of construction with feet, cast feet are standard.<br />

Not generally possible for motors with feet.<br />

5/76 Siemens D 81.1 · <strong>06</strong>/<strong>2020</strong>