© Siemens <strong>2020</strong><br />

SIMOTICS GP and SIMOTICS SD standard motors<br />

Article No. supplements and special versions · Motor protection<br />

Aluminum series SIMOTICS GP 1LE1073 and cast-iron series SIMOTICS SD 1LE1573, 1LE5773<br />

2<br />

■ Selection and ordering data<br />

Motor protection Article No. supplement Frame size Motor version<br />

1LE . . . . - . . . . . - . . ■ .<br />

Motor<br />

protection<br />

code letter<br />

15th position<br />

of the<br />

Article No.<br />

Additional<br />

identification<br />

code<br />

with<br />

order code<br />

and plain<br />

text<br />

if required<br />

Order code<br />

Standard version<br />

✓ With additional charge<br />

– Not possible<br />

Note:<br />

Options are available specifically for bearing protection – for order<br />

codes and descriptions, see from page 2/125.<br />

80 90 100 112 132 160 180 200 225 250 280 315<br />

1LE1073 IEC IE3<br />

1LE1573<br />

1LE5773<br />

Motor protection<br />

None (standard) A – <br />

1 or 3 PTC thermistors – for B – ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

tripping (2 terminals) 1)<br />

2 or 6 PTC thermistors – for C – ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

alarm and tripping<br />

(4 terminals) 1)<br />

1 KTY84-130 temperature F – ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

sensor (2 terminals) 1)<br />

2 KTY84-130 temperature G – ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

sensors (4 terminals) 1)<br />

3 Pt100 resistance<br />

H – – – ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

thermometers – 2-wire input<br />

(6 terminals)<br />

6 Pt100 resistance<br />

J – – – – – – – ✓ ✓ ✓ ✓ ✓ ✓<br />

thermometers – 2-wire input<br />

(12 terminals)<br />

1 Pt1000 resistance<br />

K – ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

thermometer (2 terminals) 2)<br />

2 Pt1000 resistance<br />

L – ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

thermometers (4 terminals) 2)<br />

1 Pt100 resistance<br />

P – – – ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

thermometer – 2-wire input<br />

(2 terminals)<br />

3 Pt100 resistance<br />

Q – – – ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

thermometers – 3-wire input<br />

(9 terminals)<br />

6 Pt100 resistance<br />

R – – – ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

thermometers – 3-wire input<br />

(18 terminals)<br />

3 NTC thermistors – for Z Q2A – – ✓ ✓ ✓ ✓ – – – – – –<br />

tripping (6 terminals)<br />

3 bimetal sensors<br />

Z Q3A ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

(NC contacts) – for tripping<br />

(2 terminals) 1)<br />

6 bimetal sensors<br />

Z Q9A – – ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

tripping (4 terminals)<br />

(NC contacts) for alarm and<br />

1)<br />

Evaluation with appropriate tripping unit (see Catalog IC 10) is recommended.<br />

2)<br />

Not UL-certified. Not in combination with option D31.<br />

2/114 Siemens D 81.1 · <strong>06</strong>/<strong>2020</strong>