© Siemens <strong>2020</strong><br />

SIMOTICS XP 1MB1, 1MB5 explosion-protected motors<br />

Orientation<br />

■ Technical specifications<br />

Rating plate<br />

The operating data for line operation is specified on the rating<br />

plate - on an additional rating plate, according to the selected<br />

product, 4 rated operating points are possible in the following<br />

variants:<br />

Possible variants<br />

50 Hz field<br />

weakening range<br />

60 Hz field<br />

weakening range<br />

Rated operating points<br />

in Hz<br />

Additional identification<br />

code voltage code 12th<br />

and 13th position of the<br />

Article No. and order code<br />

5 25 50 f max 50 Hz voltage: e.g.<br />

"90" and M4A<br />

6 30 60 f max 60 Hz voltage: e.g.<br />

"90" and M1E<br />

87 Hz characteristic 5 25 87 f max 87 Hz at 400 V:<br />

"90" and M3A<br />

f max see page 5/17 "Mechanical limit speeds of the<br />

SIMOTICS XP 1MB15, 1MB5 Ex db, Ex ec, Ex tb and Ex tc<br />

explosion-protected motors".<br />

Other voltages can be selected with the voltage code 90<br />

(12th, 13th position of the Article No.) and order code M1Y<br />

Special winding.<br />

Special case: Line operation data in two voltage levels plus converter<br />

data in one voltage level: M1Y + Y80 e.g.<br />

400 V/690 VY 50Hz DOL + 400 V VSD<br />

Insulated bearings<br />

Frame sizes 225 and 250:<br />

For converter operation it is recommended that an "insulated<br />

bearing cartridge NDE" – order code L51 be used.<br />

Frame sizes 280 to 355:<br />

For ordering with order codes B40/B41/B43/B44, the "insulated<br />

bearing cartridge NDE" is included as standard.<br />

Frame sizes 400 and 450:<br />

For ordering with order codes B40/B41/B43, the "insulated<br />

bearing cartridge NDE" is included as standard.<br />

The data on the separate rating plate for converter operation apply<br />

to both constant torque drives and pump/fan/compressor<br />

drives. For a constant torque drive, the resulting thermal motor<br />

torques in the positioning range must be taken into account.<br />

Example motor ID:<br />

Motor rating plate with line operation data and additional rating<br />

plate with converter operation data:<br />

Increased safety motor Ex ec (Zone 2) for operation on<br />

SINAMICS G180:<br />

1MB15331CB002AB4-Z<br />

M4A+B40+Y68<br />

Plain text Y68: SINAMICS G180<br />

D-90441 Nürnberg Made in Czech Rep.<br />

3~Mot. 1CV3130B 1MB15331CB002AB4-Z UD 1701/1234567 001 001 0158<br />

IEC/EN 60034 132S IMB3 IP55<br />

II 3 G<br />

67kg Th.Cl. 155(F) -20°C