SIMOTICS XP 1MB1, 1MB5 explosion-protected motors<br />

Zones 21, 22, and 2 with types of protection Ex tb, Ex tc, Ex ec · IE2 High Efficiency<br />

Aluminum series 1MB10 – self-ventilated<br />

5<br />

■ Selection and ordering data<br />

Operating values at rated power<br />

Aluminum series<br />

P rated, P rated, Frame n rated, T rated, Different rated, rated, rated, cos rated, I rated, T LR / I LR / T B / L pfA, L WA, 1MB1<br />

m IM B3 J<br />

50 Hz 60 Hz size 50 Hz 50 Hz IE class 50 Hz, 50 Hz, 50 Hz, 50 Hz, 50 Hz, T rated I rated T rated 50 Hz 50 Hz<br />

60 Hz/P60 4/4 3/4 2/4 4/4 400 V<br />

Article No.<br />

kW kW FS rpm Nm % % % A dB(A) dB(A) kg kgm 2<br />

• Cooling: self-ventilated (IC411)<br />

• Efficiency according to IEC 60034-30: IE2 High Efficiency<br />

• Insulation: Thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)<br />

6-pole: 1000 rpm at 50 Hz, 1200 rpm at 60 Hz 1)<br />

0.37 0.43 80 M 925 3.8 67.6 67.9 64.4 0.69 1.14 2.1 4 2.4 42 53 1MB10■1-0DC2■-■■■■ 9 0.0017<br />

0.55 0.63 80 M 935 5.6 73.1 73.8 70.8 0.66 1.65 2.5 4.4 2.9 42 53 1MB10■1-0DC3■-■■■■ 12 0.0025<br />

0.75 0.86 90 S 935 7.7 75.9 76.8 74.5 0.7 2.05 2 4.1 2.5 43 55 1MB10■1-0EC0■-■■■■ 13 0.003<br />

1.1 1.27 90 L 935 11 IE1 78.1 79.3 77.7 0.7 2.9 2.2 4.4 2.6 43 55 1MB10■1-0EC4■-■■■■ 16 0.004<br />

1.5 1.75 100 L 970 15 79.8 80.5 79 0.73 3.7 2 5.4 2.8 59 71 1MB10■1-1AC4■-■■■■ 25 0.011<br />

2.2 2.55 112 M 965 22 81.8 82.7 81.7 0.75 5.2 2 5 2.8 62 74 1MB10■1-1BC2■-■■■■ 29 0.014<br />

3 3.45 132 S 970 30 83.3 83.4 81 0.72 7.2 1.6 5 2.5 63 75 1MB10■1-1CC0■-■■■■ 38 0.024<br />

4 4.55 132 M 970 39 84.6 85.5 84.3 0.75 9.1 1.6 5 2.3 63 75 1MB10■1-1CC2■-■■■■ 43 0.029<br />

5.5 6.3 132 M 970 54 86 87.1 86.4 0.76 12.1 1.9 5.6 2.6 63 75 1MB10■1-1CC3■-■■■■ 52 0.037<br />

7.5 8.6 160 M 975 73 87.2 87.9 87.2 0.74 16.8 1.9 4.7 2.2 67 79 1MB10■1-1DC2■-■■■■ 77 0.075<br />

11 12.6 160 L 975 108 88.7 89.7 89.3 0.76 23.5 1.9 4.8 2.2 67 79 1MB10■1-1DC4■-■■■■ 93 0.098<br />

8-pole: 750 rpm at 50 Hz, 900 rpm at 60 Hz 1)<br />

0.75 0.86 100 L 705 10 66.2 65.7 61.6 0.61 2.7 1.5 3.2 2.1 60 72 1MB10■1-1AD4■-■■■■ 21 0.0086<br />

1.1 1.27 100 L 695 15 70.8 72.3 69.6 0.65 3.45 1.4 3.2 1.9 60 72 1MB10■1-1AD5■-■■■■ 25 0.011<br />

1.5 1.75 112 M 725 20 74.1 73.9 71.2 0.63 4.65 1.6 4 2.4 63 75 1MB10■1-1BD2■-■■■■ 34 0.017<br />

2.2 2.55 132 S 725 29 77.6 78.2 76.6 0.62 6.6 1.4 3.5 2 63 75 1MB10■1-1CD0■-■■■■ 46 0.034<br />

3 3.45 132 M 720 40 IE1 80 80.7 79.2 0.62 8.7 1.4 3.7 2 63 75 1MB10■1-1CD2■-■■■■ 52 0.037<br />

4 4.55 160 M 730 52 81.9 82.6 81.4 0.67 10.5 1.6 3.7 1.9 63 75 1MB10■1-1DD2■-■■■■ 69 0.<strong>06</strong>5<br />

5.5 6.3 160 M 730 72 83.8 84.2 83 0.67 14.1 1.7 3.9 2 63 75 1MB10■1-1DD3■-■■■■ 82 0.083<br />

7.5 8.6 160 L 725 99 85.3 86.4 86 0.7 18.1 1.6 3.8 1.9 63 75 1MB10■1-1DD4■-■■■■ 94 0.098<br />

Zones<br />

Zone 21 (conductive and non-conductive dust occasionally) Ex tb IIIC 1<br />

Zone 22 (non-conductive dust rarely or for a short period) Ex tc IIIB 2<br />

Zone 2 (explosive gases rarely or for a short period) Ex ec IIC 3<br />

Voltages Version Order code<br />

50 Hz 230 V/400 VY 60 Hz 1) 460 VY Standard 2 2 –<br />

50 Hz 400 V/690 VY 60 Hz 1) 460 V Standard 3 4 –<br />

50 Hz 500 VY Without additional charge 2 7 –<br />

50 Hz 500 V Without additional charge 4 0 –<br />

For other voltages 1) and more information, see from page 5/51 9 0 . . .<br />

Types of construction Version Order code<br />

Without flange IM B3 2) Standard A –<br />

With flange IM B5 2) With additional charge F –<br />

With flange IM B14 2) With additional charge K –<br />

For other types of construction and more information, see from page 5/56 ■ . . .<br />

Motor protection<br />

Version<br />

Without Standard A<br />

3 temperature sensors (frame sizes 80, 90 or 100 to 200) With additional charge B<br />

For other motor protection and more information, see from page 5/68<br />

■<br />

Terminal box position<br />

Version<br />

Terminal box at top Standard 4<br />

For other terminal box positions and more information, see from page 5/73<br />

■<br />

Special versions<br />

Order code(s)<br />

For options, see from page 5/78 1MB10■1- . . . . ■-■■■■ -Z . . .+. . .+. . .+. . .<br />

For footnotes, see page 5/40<br />