12.01.2021 Views

Motors-D81.1-complete-English-06-2020

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

© Siemens <strong>2020</strong><br />

SIMOTICS XP 1MB1, 1MB5 explosion-protected motors<br />

Orientation<br />

■ Technical specifications<br />

Individual drive check of variable speed drive (VSD) systems<br />

(IC411 self-ventilated motors) with configuration characteristics<br />

for converter operation – 1MB1/1MB5 motors (all types of protection).<br />

Limits for example control ranges are listed in the power tables<br />

on the following pages. For individual drive checks, the following<br />

configuration characteristics apply to frame sizes 71 to 355.<br />

For driven machine power or torque less than or equal to rated<br />

data, operation up to f max in accordance with the power tables is<br />

possible. This applies to configurations with any load torques<br />

and control ranges.<br />

The maximum admissible speed in field weakening can be calculated<br />

by dividing f max 120 by the motor's number of poles.<br />

Checking the feasibility of the required operating point<br />

To do this, (derived from reference point A)<br />

• The desired load/power P 2 must be divided by the VSD power<br />

P VSD<br />

• The desired control speed n must be divided by the VSD asynchronous<br />

speed n asyn VSD<br />

• The desired load/torque T D must be divided by the VSD torque<br />

T VSD.<br />

These calculated values should be checked afterwards against<br />

the following diagrams to determine whether the desired operating<br />

point (from speed 0) is below the VSD load/torque limit<br />

T D /T VSD and the load/power limit P 2 /P VSD.<br />

1.1<br />

1.1<br />

Torque limit T D /T VSD<br />

1<br />

0.9<br />

0.8<br />

BT<br />

Cooling method IC411 - standard<br />

AT/P<br />

1.00<br />

Cooling method IC411 - standard<br />

DP<br />

1<br />

0.9<br />

0.8<br />

Power limit P 2 /P VSD<br />

0.7<br />

CT<br />

0.7<br />

0.6<br />

0.5<br />

0.50<br />

BP<br />

DT<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

Constant flow range<br />

Field-weakening range<br />

0.4<br />

0.3<br />

5<br />

0.2<br />

0.2<br />

0.1<br />

0<br />

0<br />

CP<br />

0.1<br />

0.2<br />

0.3<br />

0.4<br />

0.5<br />

0.6<br />

0.7<br />

0.8<br />

0.9<br />

1<br />

1.1<br />

1.2<br />

1.3<br />

1.4<br />

1.5<br />

1.6<br />

1.7<br />

1.8<br />

1.9<br />

0.1<br />

0<br />

2<br />

G_D081_EN_01078<br />

Control speed nn /<br />

asyn VSD<br />

Torque limit at cooling method IC411 - standard<br />

TD<br />

/T<br />

VSD<br />

Power limit at cooling method IC411 - standard P2<br />

/P<br />

VSD<br />

Configuration characteristics for frame sizes 71 to 200<br />

AM/P: Reference point for general selecting/dimensioning<br />

AP: Typical load point for applications with square-law load<br />

torque, e.g. fans and pumps<br />

BM/CM: Typical load point for applications with constant load<br />

torque, e.g. hoisting gear, conveyor belts etc.<br />

DM/DP: Typical load point for applications with increased<br />

speed/frequency<br />

Siemens D 81.1 · <strong>06</strong>/<strong>2020</strong><br />

5/15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!