12.01.2021 Views

Motors-D81.1-complete-English-06-2020

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

© Siemens <strong>2020</strong><br />

SIMOTICS GP and SIMOTICS SD standard motors<br />

Eagle Line · NEMA Energy Efficient MG1 Table 12-11<br />

Aluminum series SIMOTICS GP 1LE1021 – self-ventilated or forced-air cooled<br />

2<br />

■ Selection and ordering data<br />

P rated,<br />

60 Hz/<br />

P50<br />

P rated,<br />

60 Hz/<br />

P60<br />

Frame<br />

size<br />

– Not required<br />

✓ Available<br />

Operating values at rated power<br />

n rated,<br />

60 Hz<br />

T rated, EISA rated,<br />

60 Hz CC No. 60 Hz,<br />

CC032A 4/4<br />

rated,<br />

60 Hz,<br />

3/4<br />

rated,<br />

60 Hz,<br />

2/4<br />

cos rated,<br />

60 Hz,<br />

4/4<br />

I rated, T LR / I LR / T B / L pfA,<br />

60 Hz, T rated, I rated, T rated, 60 Hz<br />

460 V 60 Hz 60 Hz 60 Hz<br />

L WA,<br />

60 Hz<br />

Aluminum series<br />

1LE1021<br />

Article No.<br />

kW hp FS rpm Nm % % % A dB(A) dB(A)<br />

• Cooling: Self-ventilated (IC411) or with order code F90 forced-air cooled without external fan and fan cover (IC418)<br />

• Efficiency: NEMA Energy Efficient, UL, CSA, and service factor (SF) 1.15 – for operation in the USA and Canada, not admissible for exporting to Mexico<br />

• Insulation: Thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)<br />

4-pole: 1500 rpm at 50 Hz, 1800 rpm at 60 Hz<br />

0.55 0.75 80 M 1750 3 – 75.5 74.6 71.1 0.71 1.29 2.7 6.4 3.8 55 66 1LE1021-0DB2■-■■■■ 10 0.0017<br />

6-pole: 1000 rpm at 50 Hz, 1200 rpm at 60 Hz<br />

0.37 0.5 80 M 1140 3.1 – 64 63 59.1 0.63 1.15 2.3 4.6 2.9 45 56 1LE1021-0DC2■-■■■■ 9 0.0017<br />

0.55 0.75 80 M 1135 4.6 – 68 67.4 63.7 0.61 1.66 2.9 5.2 3.6 45 56 1LE1021-0DC3■-■■■■ 12 0.0025<br />

Voltages ( 600 V) 1) Version Order code<br />

50 Hz 230 V/400 VY 60 Hz 460 VY Standard 2 2 –<br />

50 Hz 400 V 60 Hz 460 V Standard 3 4 –<br />

50 Hz 500 VY Without additional charge 2 7 –<br />

50 Hz 500 V Without additional charge 4 0 –<br />

For other voltages and more information, see from page 2/93 9 0 . . .<br />

Types of construction 2) Version Order code<br />

With flange IM B5 3) With additional charge F –<br />

With flange IM B14 3) With additional charge K –<br />

For other types of construction and more information, see from page 2/99 ■ . . .<br />

Motor protection Version Order code<br />

Without Standard A –<br />

PTC thermistor with 1 temperature sensor With additional charge B –<br />

For other motor protection and more information, see from page 2/112 ■ . . .<br />

Terminal box position<br />

Version<br />

Terminal box at top Standard 4<br />

For other terminal box positions and more information, see from page 2/115<br />

■<br />

Special versions<br />

Order code(s)<br />

Forced-air cooled motors w/o ext. fan/fan cover (IC418) 1LE1021- . . . . ■-■■■■ -Z F90 +. . .+. . .+. . .<br />

For options, see from page 2/118 1LE1021- . . . . ■-■■■■ -Z . . .+. . .+. . .+. . .<br />

m IM B3<br />

J<br />

1)<br />

2)<br />

Operating voltages only 600 V admissible in accordance with<br />

MG1 Table 12-11.<br />

Types of construction with feet are not possible for 2-pole, 4-pole and<br />

6-pole motors 200 hp in accordance with MG1 Table 12-11.<br />

3)<br />

Types derived from IM B5 (IM V3 and IM V1) and from IM B14 (IM V19 and<br />

IM V18) are possible, provided that no requirements exist for condensation<br />

drainage holes (H03) and stamping of the type on the rating plate. The<br />

basic type IM B5 or IM B14 is stamped as standard on the rating plate.<br />

For orders with condensation drainage holes (H03), the type must be<br />

specified.<br />

2/88 Siemens D 81.1 · <strong>06</strong>/<strong>2020</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!