10.07.2015 Views

Magic 600.book

Magic 600.book

Magic 600.book

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

must be supervised by a person who assumesresponsibility for their safety.7 Installation precautionsInstallation must be performed by qualified servicetechnician.Work on the electrical installation must only be carried out byauthorised specialist personnel.The load capacity and suitability of the supportingconstruction of the building in which the door operator is to beinstalled must be inspected and approved by an expert.The door operator must be fully and securely attached at allfastening points. All fastening materials must be selectedaccording to the nature of the supporting construction andthey must be able to withstand traction force of 900 N.In the event of non-conformance with theserequirements, there is a risk of injury and materialdamage caused by a falling operator or an uncontrolledmovement of the door.When drilling the fastening holes, do not damage the buildingstructure or any electrical, water or other lines.After lifting up the door operator to the ceiling, fasten it fullywith appropriate tools to prevent it from falling down. Seeillustration on page 159.Please observe appropriate industrial safety regulations andkeep children away during installation.8 Safety devices of the door operatorThe door operator has the following safety devices. Donot remove them or alter their functionality.• Automatic load switch-off during functions "OPEN" and"CLOSE"• Connection for photo cell / safety rail / optosensor• EMERGENCY stop connection: Connection of a switch(optional) to an inset door mounted in the garage door, forexample• Emergency release (see page 161 (J))9 Safety inspectionChecking load switch-offThe automatic load switch-off is a clamping and safetymechanism that is designed to prevent accidents due to amoving door.Stop the door from outside with both hands at waist height.When closing:The door must stop automatically and reverse a little if itcomes into contact with an obstruction.When opening:The door must stop automatically when it meets withresistance (if menu A7 = 1, it moves back a short distance).After load switch-off, the door operator lights flash until thenext pulse or wireless command is received.Emergency releaseCheck as per the information provided on page 161 (J).Additional safety devicesCheck for proper functioning as per the manufacturer’sinstructions.10 Controls and indicators5 Pushbutton Close door / Minus6 Pushbutton Menu / Confirm (Teach-in run)7 Pushbutton Open door / Plus8 Indicator lamp8Messages of the indicator lamp (8)Status messagesA door in end position OPENB door between the two end positionsC door in end position CLOSEDStatus messagesDuring door movement in OPEN directionC => B => A...During door movement in CLOSE directionA => B => C...L4 Set end position OPENL3 Reference run CLOSE and set end position CLOSEDL2 Teach-in run OPEN (load values)L1 Teach-in run CLOSE (load values)Err Error and error number (flashing)11 Connections1 EMERGENCY stop (green)2 Photo cell (yellow)3 Pulse5 6 7A B C1 2 312 Installation preparationsPlease note: Check that the door is working properlyand running smoothly, and adjust if necessary. Thespring tension of the door must be set in such a way that it isstable and can be opened and closed by hand smoothly andwithout jolting.• Standard and appropriate shock-proof socket approx. 10 -50 cm away from the fastening position for the head of theoperator.(For information on fuses, see the technical data.)• Only install the door operator in dry garages.Make sure the installation set for the connection is ready on<strong>Magic</strong> 600 N000924 12/2010 9 / 208

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!