2.7.2 Time inputsS 1 Temporary release timeWith rotary switch S1, the door unlocked duration isdefined for the temporary release function. If the dooris not opened during the prescribed time, it is lockedagain. Closing the door interrupts the time sequence,meaning that it is immediately locked again.If the door is still open after expiry of the timeentered at S1, the pre-alarm and then the alarm areinitiated provided the "Door monitoring" function hasnot been switched off.Switch position 0:Time increments:Switch position F:4 Seconds4 Seconds64 SecondsS 3 Alarm timeAfter expiry of the time set at S 3, the acousticalarm signal is switched off. However, alarmsignalling in the form of the yellow LED and the alarmrelay (terminals 42 to 44) remains until the alarm isacknowledged and reset.Switch position 0:Time increments:Switch position F:11 Seconds11 Seconds176 SecondsSwitch position 0:Time increments:Switch position F:11 Seconds11 Seconds176 SecondsS 2 Pre-alarm timeRotary switch S2 indicates the duration of the prealarm.If the door is not closed, after expiry of thistime an alarm is triggered.S 4Switch S 4 is not assigned.2.7.3 S 5 function variantsUsing the slide switches of the switch block S5, different switching and monitoring functions of the control systemcan be switched on or off.S 5.1 Door monitoringSwitch position “on”: The door is monitored for amaximum admissible open time. (See also"Temporary release time" and "Pre-alarm time”!)Switch position “off”: The door open time aftertemporary release or after termination of permanentunlocking when the door is open is not monitored. Adoor remaining open does not initiate an alarm.S 5.2 Temporary releaseSwitch S 5.2 only influences the function of thecontrol input terminal 4 (turn of the key to the right atthe door terminal or terminal module).In the "On" switch position and with the doorlocked, a momentary contact pulse at this inputinitiates a temporary release. (see above!)In the "Off" switching position, only the controlcommand "lock" can be issued at terminal 4.Temporary release via terminals 27 and 28 is notinfluenced by the position of S 5.2.S 5.3 Permanent unlocking, no delaySwitch S 5.3 influences the function of the controlinput terminal 3 (turning the key to the left at theterminal) and terminal 40 (central panel).In the "On" switch position, a continuous unlockingcommand is accepted without delay.In the "Off" switch position, a continuous unlockingcommand is accepted only if the signal is active forlonger than 5 seconds.The function of the control input "Permanentunlocking" at terminals 29 and 30 is not influenced bythe position of S 5.3.79

Hurra! Ihre Datei wurde hochgeladen und ist bereit für die Veröffentlichung.

Erfolgreich gespeichert!

Leider ist etwas schief gelaufen!