• Enclosure Warning Temperature Threshold<br />

• Enclosure Critical Temperature Threshold<br />

• Controller Warning Temperature Threshold<br />

• Controller Critical Temperature Threshold<br />

6. Click the Submit button.<br />

The changes take effect immediately.<br />

Viewing FRU VPD Information<br />

113<br />

Chapter 4: Management with WebPAM PROe<br />

FRU VPD refers to Vital <strong>Product</strong> Data (VPD) information about Field Replaceable<br />

Units (FRU) in the enclosure. The number and type of FRU depends on the<br />

subsystem model.<br />

To view FRU VPD information:<br />

1. Click the Subsystem icon in Tree View.<br />

2. Click the Enclosures icon.<br />

3. Click the Enclosure icon.<br />

4. Click the FRU VPD tab in Management View.<br />

Use this information when communicating with Technical Support and when<br />

ordering replacement units. For contact information, see “Contacting Technical<br />

Support” on page 305.<br />

Checking the Batteries<br />

The Enclosure–Battery tab displays information about the cache backup battery<br />

(or batteries) in the <strong>VTrak</strong> subsystem enclosure. To check the batteries:<br />

1. Click the Subsystem icon in Tree View.<br />

2. Click the Enclosures icon.<br />

3. Click the Enclosure icon.<br />

4. Click the Battery tab in Management View.<br />

Battery Notes<br />

Each battery works with a controller. If the battery is present in the subsystem but<br />

the corresponding controller is not present, the battery will not appear in the<br />

interface.<br />

If a battery does not reflect normal conditions and it is not currently under<br />

reconditioning, run the Recondition function before you replace the battery. See<br />

“Reconditioning a Battery” on page 114.<br />

Reconditioning fully discharges, then fully recharges the battery. During<br />

reconditioning, if the Adaptive Writeback Cache function is enabled, the controller